Solar Calculator Canada

Solar Power Calculator for Ferintosh, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ferintosh
  • GPS Coordinates: 52.7658333, -112.9716667
  • Elevation: 762 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ferintosh: 43o
  • Average yearly irradiance: 1466.12 kWh/m2
  • Average yearly power output: 123714 kWh
Sun Path Ferintosh

Average yearly irradiance delivered by the Sun in Ferintosh is 1466.12/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 123714 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.68 52.21
February 2.59 72.4
March 3.47 107.71
April 5.11 153.2
May 5.85 181.41
June 5.76 172.71
July 6.29 194.91
August 5.73 177.49
September 4.75 142.46
October 3.4 105.52
November 2.09 62.83
December 1.4 43.27
Total yearly 1466.12

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.96 4834.83
February 236.37 6618.32
March 307.06 9518.81
April 437.49 13124.8
May 486.69 15087.5
June 467.58 14027.4
July 503.22 15599.9
August 461.61 14310
September 393.4 11801.9
October 293.93 9111.88
November 188.61 5658.35
December 129.67 4019.86
Total yearly 123714

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ferintosh solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 94.64 2933.96
February 164.97 4619.1
March 254.56 7891.42
April 413.2 12396.1
May 501.82 15556.4
June 502.46 15073.9
July 529.74 16422.1
August 451.01 13981.3
September 341.78 10253.4
October 222.08 6884.52
November 121.09 3632.67
December 75.58 2343.12
Total yearly 111988

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 108.3 3357.31
February 181.49 5081.79
March 268.31 8317.63
April 423.18 12695.5
May 504.44 15637.6
June 501.14 15034.2
July 530.63 16449.6
August 458.75 14221.3
September 356.3 10688.9
October 239.14 7413.22
November 136.2 4085.85
December 87.53 2713.51
Total yearly 115696

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.82 3745.54
February 196.41 5499.48
March 280.21 8686.56
April 430.86 12925.8
May 504.6 15642.5
June 497.47 14924
July 528.91 16396.3
August 464.08 14386.6
September 368.53 11055.8
October 254.4 7886.25
November 150 4500.09
December 98.5 3053.42
Total yearly 118702

Ferintosh Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.18 4097.66
February 209.7 5871.5
March 290.24 8997.51
April 435.99 13079.7
May 502.53 15578.5
June 491.57 14747.1
July 524.95 16273.6
August 466.8 14470.9
September 378.43 11352.8
October 267.81 8302.14
November 162.47 4874.22
December 108.46 3362.21
Total yearly 121008

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.62% temperature and irradiance loss. This totals to about -15.62%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.