Solar Calculator Canada

Solar Power Calculator for Bancroft, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bancroft
  • GPS Coordinates: 45.055, -77.7577778
  • Elevation: 319 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bancroft: 38o
  • Average yearly irradiance: 1559.04 kWh/m2
  • Average yearly power output: 131277 kWh
Sun Path Bancroft

Average yearly irradiance delivered by the Sun in Bancroft is 1559.04/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 131277 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.75 85.34
February 3.78 105.91
March 4.84 150.11
April 5.09 152.72
May 5.48 169.75
June 5.41 162.17
July 5.79 179.57
August 5.51 170.71
September 4.66 139.74
October 3.31 102.72
November 2.63 78.83
December 1.98 61.47
Total yearly 1559.04

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 258.03 7998.91
February 351.25 9835.13
March 431.92 13389.6
April 432.22 12966.6
May 447.61 13876
June 431.56 12946.9
July 458.01 14198.2
August 438.57 13595.7
September 378.05 11341.4
October 279.38 8660.72
November 229.74 6892.06
December 179.86 5575.73
Total yearly 131277

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bancroft solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.91 5825.18
February 280.23 7846.4
March 383.7 11894.8
April 425.37 12761.2
May 472.92 14660.6
June 469.27 14078.1
July 491.24 15228.3
August 444.09 13766.8
September 350.96 10528.9
October 237.18 7352.73
November 173.96 5218.87
December 128.63 3987.6
Total yearly 123149

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.27 6394.22
February 299.48 8385.51
March 398.62 12357.1
April 431.12 12933.5
May 471.71 14623
June 465.26 13957.9
July 488.37 15139.5
August 447.14 13861.4
September 360.71 10821.2
October 249.26 7727.01
November 188.69 5660.73
December 141.93 4399.78
Total yearly 126261

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 222.84 6908.19
February 316.57 8863.85
March 411.04 12742.1
April 434.54 13036.2
May 468.12 14511.7
June 458.95 13768.4
July 483.2 14979.3
August 447.84 13883
September 368.32 11049.7
October 259.72 8051.19
November 201.94 6058.21
December 154 4773.95
Total yearly 128626

Bancroft Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 237.62 7366.13
February 331.43 9280.15
March 420.93 13048.8
April 435.64 13069.2
May 462.24 14329.4
June 450.38 13511.3
July 475.52 14741
August 446.32 13836
September 373.82 11214.6
October 268.52 8324.21
November 213.67 6410.11
December 164.81 5108.96
Total yearly 130240

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.85% angle of incidence loss and -3.69% temperature and irradiance loss. This totals to about -15.8%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BoisbriandRosem�reSainte-Th�r�seSaint-AmableLorraineBois-des-FilionBrownsburg-ChathamCharlemagneSaint-ColombanMascoucheL'�piphanieBarkmereSaint-Joseph-de-SorelCap-Sant�NeuvilleSaint-Augustin-de-DesmauresSainte-Catherine-de-la-Jacques-CartierFossambault-sur-le-LacLac-SergentShannonLac-Saint-JosephLac-DelageSainte-Brigitte-de-LavalBeaupr�ColwoodMurdochville