Solar Calculator Canada

Solar Power Calculator for Dryden, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Dryden
  • GPS Coordinates: 49.7833333, -92.7652777
  • Elevation: 381 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Dryden: 42o
  • Average yearly irradiance: 1477.26 kWh/m2
  • Average yearly power output: 125945 kWh
Sun Path Dryden

Average yearly irradiance delivered by the Sun in Dryden is 1477.26/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 125945 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.27 70.35
February 3.62 101.47
March 4.43 137.26
April 5.52 165.46
May 5.21 161.47
June 5.29 158.56
July 5.62 174.08
August 5.32 164.82
September 4.46 133.82
October 3.11 96.45
November 1.95 58.64
December 1.77 54.89
Total yearly 1477.26

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.28 6797.6
February 343.97 9631.04
March 400.22 12406.9
April 475.62 14268.7
May 432.4 13404.3
June 425.07 12752.1
July 446.07 13828.3
August 425.79 13199.5
September 366.62 10998.7
October 265.67 8235.67
November 173.91 5217.43
December 167.91 5205.12
Total yearly 125945

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Dryden solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.69 4454.26
February 253.58 7100.1
March 339.57 10526.6
April 455.81 13674.4
May 454.59 14092.2
June 464.42 13932.5
July 477.66 14807.4
August 426.45 13220
September 329.26 9877.94
October 212.18 6577.69
November 121.85 3655.64
December 106.17 3291.34
Total yearly 115210

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.06 4993.01
February 275.27 7707.46
March 356.08 11038.6
April 465.35 13960.5
May 455.48 14119.8
June 461.47 13844.2
July 476.56 14773.4
August 431.47 13375.5
September 340.82 10224.7
October 225.61 6994
November 133.99 4019.76
December 120.29 3728.97
Total yearly 118780

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.89 5483.44
February 294.7 8251.61
March 370.22 11477
April 472.24 14167.1
May 454.04 14075.2
June 457.09 13712.6
July 473.7 14684.8
August 434.1 13457.2
September 350.29 10508.7
October 237.46 7361.37
November 145 4350.06
December 133.18 4128.44
Total yearly 121658

Dryden Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.12 5924.67
February 311.85 8731.78
March 381.97 11840.9
April 476.47 14294.2
May 450.29 13958.9
June 450.17 13505.1
July 468.36 14519.2
August 434.44 13467.6
September 357.64 10729.2
October 247.7 7678.66
November 154.85 4645.52
December 144.81 4489.09
Total yearly 123785

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.82% angle of incidence loss and -2.52% temperature and irradiance loss. This totals to about -14.74%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BoisbriandRosem�reSainte-Th�r�seSaint-AmableLorraineBois-des-FilionBrownsburg-ChathamCharlemagneSaint-ColombanMascoucheL'�piphanieBarkmereSaint-Joseph-de-SorelCap-Sant�NeuvilleSaint-Augustin-de-DesmauresSainte-Catherine-de-la-Jacques-CartierFossambault-sur-le-LacLac-SergentShannonLac-Saint-JosephLac-DelageSainte-Brigitte-de-LavalBeaupr�ColwoodMurdochville