Solar Calculator Canada

Solar Power Calculator for Minburn, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Minburn
  • GPS Coordinates: 53.3155556, -111.3641667
  • Elevation: 636 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Minburn: 44o
  • Average yearly irradiance: 1452.85 kWh/m2
  • Average yearly power output: 123695 kWh
Sun Path Minburn

Average yearly irradiance delivered by the Sun in Minburn is 1452.85/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 123695 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.6 49.62
February 2.48 69.56
March 3.59 111.29
April 5.02 150.72
May 5.79 179.47
June 5.55 166.47
July 6.22 192.71
August 5.61 173.78
September 4.79 143.62
October 3.53 109.55
November 2.05 61.42
December 1.44 44.63
Total yearly 1452.85

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.86 4707.56
February 232.54 6511.05
March 323.76 10036.5
April 433.76 13012.9
May 482.81 14967.2
June 451.18 13535.5
July 500.49 15515.1
August 454.48 14089
September 399.02 11970.5
October 307.04 9518.12
November 186.57 5597.23
December 136.6 4234.7
Total yearly 123695

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Minburn solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 89.94 2788.07
February 160.88 4504.7
March 265.36 8226.13
April 408.59 12257.8
May 498.35 15448.7
June 487 14610
July 527.69 16358.2
August 444.13 13767.9
September 343.22 10296.7
October 226.81 7031.1
November 116.64 3499.34
December 76.5 2371.56
Total yearly 111160

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.4 3205.38
February 177.09 4958.61
March 280.3 8689.18
April 418.75 12562.5
May 501.31 15540.7
June 485.79 14573.7
July 528.83 16393.8
August 451.8 14005.7
September 358.45 10753.6
October 245.37 7606.49
November 131.85 3955.59
December 89.46 2773.21
Total yearly 115018

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.77 3588.8
February 191.77 5369.43
March 293.28 9091.69
April 426.49 12794.8
May 501.85 15557.4
June 482.29 14468.6
July 527.36 16348.1
August 457.14 14171.2
September 371.34 11140.1
October 262.03 8123.02
November 145.79 4373.75
December 101.38 3142.63
Total yearly 118170

Minburn Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 127.01 3937.24
February 204.87 5736.33
March 304.28 9432.76
April 431.78 12953.4
May 500.11 15503.5
June 476.61 14298.3
July 523.37 16224.3
August 460.09 14262.8
September 381.84 11455.1
October 276.74 8579.05
November 158.41 4752.38
December 112.22 3478.93
Total yearly 120614

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.74% temperature and irradiance loss. This totals to about -14.86%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.