Solar Calculator Canada

Solar Power Calculator for Strome, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Strome
  • GPS Coordinates: 52.8108333, -112.0672222
  • Elevation: 691 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Strome: 43o
  • Average yearly irradiance: 1450.15 kWh/m2
  • Average yearly power output: 122735 kWh
Sun Path Strome

Average yearly irradiance delivered by the Sun in Strome is 1450.15/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 122735 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.65 51.24
February 2.44 68.32
March 3.43 106.37
April 5.09 152.75
May 5.82 180.41
June 5.61 168.41
July 6.28 194.65
August 5.7 176.84
September 4.71 141.4
October 3.4 105.33
November 2.05 61.51
December 1.38 42.92
Total yearly 1450.15

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.06 4806.9
February 225.63 6317.6
March 305.98 9485.32
April 437.37 13121
May 484.35 15014.9
June 455.82 13674.6
July 503.41 15605.7
August 460.4 14272.3
September 390.93 11728
October 293.78 9107.2
November 185.74 5572.18
December 129.99 4029.84
Total yearly 122735

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Strome solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.96 2881.81
February 156.6 4384.89
March 252.11 7815.33
April 412.74 12382.1
May 500.03 15501
June 491.06 14731.8
July 530.62 16449.1
August 449.81 13944.1
September 339.2 10175.9
October 221.27 6859.29
November 118.58 3557.44
December 75.15 2329.57
Total yearly 111012

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.71 3307.94
February 172.5 4829.91
March 266.07 8248.16
April 422.8 12684.1
May 502.69 15583.5
June 489.65 14689.6
July 531.49 16476.1
August 457.54 14183.7
September 353.67 10610.2
October 238.41 7390.62
November 133.52 4005.54
December 87.2 2703.18
Total yearly 114713

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.33 3699.27
February 186.87 5232.33
March 278.18 8623.63
April 430.53 12915.8
May 502.9 15589.8
June 485.95 14578.4
July 529.73 16421.6
August 462.88 14349.3
September 365.87 10976.2
October 253.75 7866.3
November 147.18 4415.49
December 98.27 3046.4
Total yearly 117714

Strome Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.8 4054.75
February 199.69 5591.4
March 288.42 8940.98
April 435.74 13072.2
May 500.85 15526.2
June 480.05 14401.6
July 525.58 16292.9
August 465.72 14437.4
September 375.75 11272.6
October 267.25 8284.82
November 159.53 4786.04
December 108.34 3358.52
Total yearly 120019

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -3.31% temperature and irradiance loss. This totals to about -15.36%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

JolietteSorel-TracyVictoriavilleThetford MinesMont-TremblantSaint-GeorgesNorth BayTrois-Rivi�resManiwakiElliot LakeSummersideSainte-MarieMont-LaurierDonnaconaTemiscamingL�visSaint-PamphileMontmagnyMiramichiSainte-Anne-de-Beaupr�Ville-MarieLa Pocati�reEdmundstonLa TuqueBaie-Saint-PaulMurdochville