Solar Calculator Canada

Solar Power Calculator for Manitou, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Manitou
  • GPS Coordinates: 49.240555, -98.536667
  • Elevation: 492 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Manitou: 43o
  • Average yearly irradiance: 1611.66 kWh/m2
  • Average yearly power output: 138302 kWh
Sun Path Manitou

Average yearly irradiance delivered by the Sun in Manitou is 1611.66/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 138302 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.44 75.59
February 3.6 100.89
March 3.95 122.38
April 5.61 168.37
May 5.43 168.31
June 5.76 172.84
July 6.43 199.33
August 5.98 185.24
September 5.14 154.19
October 3.9 120.81
November 2.62 78.53
December 2.1 65.17
Total yearly 1611.66

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 237.24 7354.51
February 345.44 9672.35
March 357.73 11089.8
April 485.32 14559.6
May 454.44 14087.7
June 466.95 14008.4
July 515.77 15988.7
August 481.61 14929.9
September 426.31 12789.4
October 338.35 10488.8
November 237.62 7128.53
December 200.16 6204.83
Total yearly 138302

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Manitou solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.09 4683.77
February 249.54 6987.08
March 304.69 9445.45
April 465.12 13953.5
May 479.35 14859.7
June 512.52 15375.6
July 554.38 17185.7
August 479.18 14854.5
September 378.62 11358.6
October 262.64 8141.92
November 160.78 4823.41
December 122.16 3786.86
Total yearly 125456

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.46 5284.34
February 271.99 7615.67
March 319.11 9892.51
April 475.2 14256
May 479.98 14879.3
June 509.27 15278.2
July 553.38 17154.8
August 485.87 15062
September 393.01 11790.4
October 281.1 8714.22
November 178.28 5348.34
December 139.55 4326.09
Total yearly 129602

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 188.18 5833.67
February 292.18 8181.15
March 331.41 10273.8
April 482.55 14476.5
May 478.38 14829.9
June 503.69 15110.8
July 549.92 17047.5
August 489.83 15184.7
September 404.9 12146.9
October 297.5 9222.39
November 194.2 5825.93
December 155.53 4821.56
Total yearly 132955

Manitou Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.2 6330.24
February 310.08 8682.3
March 341.56 10588.4
April 486.99 14609.6
May 475.01 14725.3
June 496.2 14886
July 543.91 16861.3
August 491.03 15222.1
September 414.24 12427.2
October 311.77 9664.88
November 208.49 6254.79
December 170.05 5271.45
Total yearly 135523

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -1.98% temperature and irradiance loss. This totals to about -14.19%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

EngleeRegina BeachBassanoCentral ButteBalcarresKyleLangenburgChurchbridgeConcheBredenburySoutheyCuparChestermereSaltcoatsStrathmoreCraikSte. Rose du LacStrasbourgGilbert PlainsMain BrookItunaGrandviewElroseCochraneEatoniaMurdochville