Solar Calculator Canada

Solar Power Calculator for Oak Lake, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Oak Lake
  • GPS Coordinates: 49.766389, -100.62806
  • Elevation: 435 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Oak Lake: 42o
  • Average yearly irradiance: 1589.81 kWh/m2
  • Average yearly power output: 135693 kWh
Sun Path Oak Lake

Average yearly irradiance delivered by the Sun in Oak Lake is 1589.81/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 135693 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.23 69.01
February 3.37 94.34
March 3.87 120.02
April 5.64 169.18
May 5.59 173.36
June 5.75 172.64
July 6.39 198.16
August 5.94 184.15
September 5.15 154.37
October 3.85 119.22
November 2.52 75.49
December 1.93 59.87
Total yearly 1589.81

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 214.78 6658.04
February 321.46 9000.8
March 350.5 10865.7
April 486.22 14586.8
May 465.97 14444.9
June 464.98 13949.4
July 510.03 15811
August 477.38 14798.6
September 425.11 12753.4
October 332.66 10312.4
November 227.8 6834.07
December 183.16 5677.81
Total yearly 135693

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Oak Lake solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 137.82 4272.28
February 232.3 6504.53
March 298.91 9266.23
April 465.07 13952.1
May 488.8 15152.9
June 508.81 15264.5
July 546.28 16934.6
August 474.68 14715.1
September 376.18 11285.5
October 257.68 7988.21
November 154.02 4620.52
December 112.72 3494.28
Total yearly 123451

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.25 4812.6
February 253.22 7090.17
March 312.89 9699.55
April 475.22 14256.5
May 490.04 15191.3
June 505.93 15178
July 545.84 16921.2
August 481.28 14919.5
September 390.77 11723.2
October 275.97 8555.18
November 170.89 5126.85
December 128.53 3984.41
Total yearly 127459

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.15 5305.78
February 272.02 7616.44
March 324.82 10069.4
April 482.62 14478.7
May 489.03 15159.8
June 500.78 15023.4
July 542.99 16832.8
August 485.17 15040.3
September 402.89 12086.6
October 292.23 9059.26
November 186.25 5587.37
December 143.01 4433.25
Total yearly 130693

Oak Lake Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.51 5750.78
February 288.66 8082.38
March 334.67 10374.8
April 487.34 14620.3
May 485.57 15052.6
June 493.83 14814.9
July 536.99 16646.7
August 486.39 15078.1
September 412.45 12373.5
October 306.41 9498.84
November 200.03 6000.83
December 156.12 4839.68
Total yearly 133133

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -2.52% temperature and irradiance loss. This totals to about -14.65%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

AllanDelisleBowdenSturgisPreecevilleColonsayLeroyLuselandMinitonasCoronationWatsonAsquithPenholdKelvingtonCastorBrunoRose ValleySylvan LakeMary's HarbourVondaAberdeenMacklinDalmenyLanghamEckvilleMurdochville