Solar Calculator Canada

Solar Power Calculator for Birtle, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Birtle
  • GPS Coordinates: 50.4225, -101.0475
  • Elevation: 479 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Birtle: 43o
  • Average yearly irradiance: 1561.02 kWh/m2
  • Average yearly power output: 133708 kWh
Sun Path Birtle

Average yearly irradiance delivered by the Sun in Birtle is 1561.02/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 133708 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.14 66.41
February 3.26 91.15
March 3.74 115.86
April 5.58 167.45
May 5.68 175.93
June 5.69 170.55
July 6.38 197.9
August 5.77 179
September 5.05 151.54
October 3.8 117.83
November 2.35 70.62
December 1.83 56.79
Total yearly 1561.02

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 207.44 6430.79
February 311.48 8721.38
March 339.09 10511.8
April 482.78 14483.5
May 474.55 14711.1
June 461.08 13832.5
July 512.18 15877.5
August 466.58 14464
September 420.19 12605.8
October 330.65 10250.1
November 214.01 6420.38
December 174.16 5398.82
Total yearly 133708

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Birtle solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.68 4051.13
February 222.86 6240.04
March 286.38 8877.74
April 460.66 13819.7
May 497.36 15418.2
June 504.31 15129.4
July 546.58 16944
August 463.81 14378.2
September 370.21 11106.3
October 254.01 7874.38
November 143.46 4303.9
December 105.17 3260.25
Total yearly 121403

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.81 4582.08
February 243.46 6816.95
March 300.37 9311.34
April 471.04 14131.1
May 498.89 15465.6
June 501.75 15052.4
July 546.57 16943.7
August 470.31 14579.7
September 384.85 11545.6
October 272.49 8447.1
November 159.44 4783.27
December 120.44 3733.62
Total yearly 125392

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 163.43 5066.36
February 261.98 7335.47
March 312.35 9683
April 478.66 14360
May 498.13 15442.1
June 496.92 14907.5
July 544.07 16866
August 474.16 14699
September 397.07 11912
October 288.94 8957.03
November 173.97 5219.14
December 134.42 4166.87
Total yearly 128614

Birtle Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 177.52 5503.27
February 278.39 7794.86
March 322.32 9991.77
April 483.6 14508
May 494.83 15339.9
June 490.33 14710
July 538.42 16691
August 475.46 14739.3
September 406.76 12202.8
October 303.31 9402.63
November 187.01 5610.45
December 147.07 4559.1
Total yearly 131053

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -2.18% temperature and irradiance loss. This totals to about -14.35%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: