Solar Calculator Canada

Solar Power Calculator for Burstall, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Burstall
  • GPS Coordinates: 50.6556306, -109.9093722
  • Elevation: 728 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Burstall: 42o
  • Average yearly irradiance: 1590.32 kWh/m2
  • Average yearly power output: 133773 kWh
Sun Path Burstall

Average yearly irradiance delivered by the Sun in Burstall is 1590.32/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133773 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.96 60.83
February 2.93 81.96
March 4.1 127.07
April 5.52 165.6
May 5.89 182.58
June 5.79 173.62
July 6.6 204.68
August 6.19 192.02
September 5.24 157.29
October 4 124
November 2.38 71.46
December 1.59 49.21
Total yearly 1590.32

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 182.12 5645.57
February 267.27 7483.46
March 360.21 11166.7
April 472.29 14168.8
May 488.67 15148.7
June 467.42 14022.5
July 523.87 16240
August 494.74 15337
September 430.82 12924.5
October 344.26 10672
November 213.53 6405.95
December 147.02 4557.66
Total yearly 133773

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Burstall solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.99 3564.8
February 193.23 5410.32
March 304.62 9443.23
April 448.64 13459.1
May 508.75 15771.4
June 508.05 15241.6
July 556.69 17257.4
August 485.78 15059.3
September 377.05 11311.5
October 263.5 8168.38
November 143.61 4308.27
December 89.14 2763.42
Total yearly 121759

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.31 4039.64
February 210.93 5906.04
March 319.61 9907.76
April 458.74 13762.1
May 510.6 15828.5
June 505.45 15163.4
July 556.42 17248.9
August 493.49 15298.1
September 392.65 11779.5
October 283.19 8778.94
November 159.74 4792.29
December 102.24 3169.51
Total yearly 125675

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.34 4474.67
February 226.87 6352.22
March 332.48 10306.8
April 466.24 13987.1
May 510.02 15810.7
June 500.48 15014.4
July 553.4 17155.3
August 498.56 15455.5
September 405.71 12171.2
October 300.76 9323.62
November 174.46 5233.69
December 114.25 3541.77
Total yearly 128827

Burstall Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 157.05 4868.57
February 241 6748
March 343.21 10639.4
April 471.12 14133.6
May 506.75 15709.3
June 493.79 14813.8
July 548.11 16991.3
August 500.94 15529.1
September 416.17 12485.1
October 316.16 9800.83
November 187.7 5631.11
December 125.14 3879.35
Total yearly 131229

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -3.94% temperature and irradiance loss. This totals to about -15.88%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Birch HillsMaidstoneVikingMilletArborfieldLashburnShellbrookThorsbyCalmarCarrot RiverDevonSpiritwoodTofieldTurtlefordChoicelandStony PlainMundareSt. WalburgTwo HillsLamontBruderheimMorinvilleGibbonsBig RiverBon AccordMurdochville