Solar Calculator Canada

Solar Power Calculator for Port Blandford, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Port Blandford
  • GPS Coordinates: 48.3414861, -54.1775472
  • Elevation: 70 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Port Blandford: 39o
  • Average yearly irradiance: 1261.08 kWh/m2
  • Average yearly power output: 107211 kWh
Sun Path Port Blandford

Average yearly irradiance delivered by the Sun in Port Blandford is 1261.08/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 107211 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.83 56.83
February 2.6 72.73
March 3.2 99.05
April 4.25 127.58
May 4.63 143.44
June 4.73 141.99
July 5.02 155.53
August 4.37 135.44
September 3.99 119.62
October 2.89 89.68
November 2.23 66.79
December 1.69 52.41
Total yearly 1261.08

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.17 5213.33
February 237.32 6644.88
March 285.61 8853.99
April 369.02 11070.5
May 389.85 12085.3
June 388.85 11665.6
July 404.74 12547.1
August 353.46 10957.1
September 330.32 9909.52
October 246.84 7652.06
November 196.3 5888.86
December 152.36 4723.15
Total yearly 107211

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Port Blandford solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.03 3659.01
February 185.39 5190.89
March 254.31 7883.76
April 362.06 10862
May 409.23 12686.2
June 419.24 12577.2
July 429.66 13319.4
August 357.51 11082.9
September 303.48 9104.4
October 203.7 6314.55
November 141.61 4248.3
December 101.47 3145.64
Total yearly 100074

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.51 4045.95
February 198.93 5570.09
March 263.85 8179.38
April 367.3 11019
May 408.62 12667.2
June 416.19 12485.7
July 428.19 13274
August 360.13 11164
September 312.6 9378.08
October 215.43 6678.2
November 155.38 4661.37
December 113.97 3533.04
Total yearly 102656

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.89 4398.56
February 211.01 5908.31
March 271.81 8426.02
April 370.64 11119.3
May 406.29 12594.9
June 411.39 12341.8
July 424.99 13174.6
August 360.95 11189.6
September 319.9 9596.94
October 225.72 6997.2
November 167.87 5035.98
December 125.44 3888.51
Total yearly 104672

Port Blandford Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 152.12 4715.6
February 221.59 6204.55
March 278.16 8622.85
April 371.91 11157.5
May 402.56 12479.3
June 405.33 12159.8
July 419.74 13011.9
August 360.02 11160.5
September 325.33 9760.01
October 234.53 7270.38
November 179.03 5370.93
December 135.82 4210.54
Total yearly 106124

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.01% angle of incidence loss and -2.61% temperature and irradiance loss. This totals to about -14.98%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

VulcanGrenfellMorseWolseleyBirtleHerbertWhite CityShoal LakeSintalutaPilot ButteBalgonieEricksonWinnipeg BeachRiver of PondsQu'AppelleHawke's BayCabriLumsdenBurstallPort SaundersRossburnTurner ValleyBlack DiamondOkotoksLembergMurdochville