Solar Calculator Canada

Solar Power Calculator for Winterton, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Winterton
  • GPS Coordinates: 47.9528333, -53.3144861
  • Elevation: 87 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Winterton: 34o
  • Average yearly irradiance: 1226.92 kWh/m2
  • Average yearly power output: 104940 kWh
Sun Path Winterton

Average yearly irradiance delivered by the Sun in Winterton is 1226.92/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 104940 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.2 37.29
February 1.96 54.84
March 2.97 92.12
April 4.4 132.1
May 4.87 150.95
June 5.09 152.79
July 5.2 161.33
August 4.69 145.37
September 4.15 124.43
October 2.71 83.98
November 1.86 55.84
December 1.16 35.87
Total yearly 1226.92

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.83 3156.61
February 167.33 4685.12
March 253.97 7872.96
April 375.57 11267.2
May 415.68 12886
June 434.22 13026.6
July 445.39 13807.1
August 401.84 12456.9
September 356.46 10693.8
October 233.19 7228.76
November 160.61 4818.26
December 98.08 3040.47
Total yearly 104940

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Winterton solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 82.05 2543.68
February 143.43 4016
March 233.6 7241.55
April 367.08 11012.5
May 428.59 13286.1
June 457.29 13718.7
July 462.52 14338.1
August 400.42 12412.9
September 329.82 9894.62
October 200.12 6203.87
November 125.75 3772.38
December 75.08 2327.37
Total yearly 100768

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 88.09 2730.77
February 150.96 4227.01
March 240.69 7461.32
April 372.1 11162.9
May 427.76 13260.5
June 453.76 13612.7
July 460.66 14280.5
August 403.53 12509.5
September 339.41 10182.4
October 210.54 6526.73
November 136.26 4087.85
December 81.96 2540.89
Total yearly 102583

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.47 2897.64
February 157.53 4410.71
March 246.44 7639.78
April 375.18 11255.4
May 425.21 13181.4
June 448.38 13451.5
July 456.94 14165.1
August 404.72 12546.2
September 347.03 10411
October 219.57 6806.6
November 145.68 4370.48
December 88.18 2733.46
Total yearly 103869

Winterton Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.19 3044
February 163.1 4566.79
March 250.86 7776.58
April 376.32 11289.6
May 421.36 13062
June 441.88 13256.3
July 451.37 13992.6
August 403.93 12521.9
September 352.67 10580
October 227.2 7043.05
November 154 4619.9
December 93.7 2904.72
Total yearly 104657

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.03% angle of incidence loss and -2% temperature and irradiance loss. This totals to about -14.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

VulcanGrenfellMorseWolseleyBirtleHerbertWhite CityShoal LakeSintalutaPilot ButteBalgonieEricksonWinnipeg BeachRiver of PondsQu'AppelleHawke's BayCabriLumsdenBurstallPort SaundersRossburnTurner ValleyBlack DiamondOkotoksLembergMurdochville