The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Cornwall
  • GPS Coordinates: 45.0263889, -74.7263889
  • Elevation: 59 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Cornwall: 38o
  • Average yearly irradiance: 1542.96 kWh/m2
  • Average yearly power output: 128699 kWh
Sun Path Cornwall

Average yearly irradiance delivered by the Sun in Cornwall is 1542.96/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 128699 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.65 82.05
February 3.39 94.87
March 4.47 138.45
April 5 150.03
May 5.53 171.38
June 5.45 163.36
July 5.87 182.1
August 5.64 174.92
September 4.83 144.78
October 3.32 102.83
November 2.71 81.19
December 1.84 56.99
Total yearly 1542.96

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 245.45 7608.81
February 311.41 8719.38
March 396.11 12279.3
April 421.7 12651
May 448.56 13905.3
June 431.65 12949.4
July 461.1 14294.1
August 446.62 13845.1
September 388.34 11650.1
October 277.83 8612.61
November 235.49 7064.62
December 165.13 5118.99
Total yearly 128699

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Cornwall solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.35 5559.87
February 251.41 7039.6
March 354.04 10975.3
April 414.77 12443
May 471.42 14614
June 466.76 14002.9
July 492.62 15271.3
August 451.23 13988.2
September 359.88 10796.5
October 235.34 7295.5
November 179.31 5379.37
December 119.63 3708.41
Total yearly 121074

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 196.89 6103.61
February 268.03 7504.96
March 367.31 11386.5
April 420.23 12606.9
May 470.48 14585
June 462.99 13889.7
July 490.02 15190.7
August 454.48 14088.8
September 370.11 11103.2
October 247.56 7674.33
November 194.36 5830.86
December 131.62 4080.13
Total yearly 124045

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 212.75 6595.29
February 282.71 7915.99
March 378.31 11727.5
April 423.45 12703.6
May 467.21 14483.4
June 456.99 13709.6
July 484.98 15034.5
August 455.34 14115.6
September 378.14 11344.1
October 258.16 8003.05
November 207.88 6236.44
December 142.47 4416.52
Total yearly 126286

Cornwall Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 226.89 7033.7
February 295.42 8271.88
March 387.01 11997.4
April 424.42 12732.7
May 461.63 14310.5
June 448.8 13464
July 477.55 14804.1
August 453.83 14068.6
September 383.94 11518.2
October 267.12 8280.57
November 219.84 6595.13
December 152.16 4716.91
Total yearly 127794

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -4.65% temperature and irradiance loss. This totals to about -16.59%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.