The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Collingwood
  • GPS Coordinates: 44.5014, -80.24071
  • Elevation: 181 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Collingwood: 35o
  • Average yearly irradiance: 1545.29 kWh/m2
  • Average yearly power output: 130710 kWh
Sun Path Collingwood

Average yearly irradiance delivered by the Sun in Collingwood is 1545.29/kWh/m2 at the optimal panel slope of 35o. After taking all losses into account, you can expect about 130710 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 35o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.81 56.16
February 2.72 76.14
March 4.55 141.14
April 5.37 161.1
May 5.89 182.56
June 5.99 179.75
July 6.29 194.87
August 5.79 179.6
September 4.9 147.05
October 3.41 105.7
November 2.45 73.59
December 1.54 47.64
Total yearly 1545.29

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.78 5139.09
February 251.14 7032.04
March 411.24 12748.4
April 466.23 13986.8
May 493.07 15285.2
June 488.44 14653.1
July 504.95 15653.5
August 467.02 14477.6
September 401.79 12053.8
October 290.12 8993.71
November 214.6 6437.87
December 137.05 4248.61
Total yearly 130710

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Collingwood solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.05 4062.66
February 210.87 5904.39
March 371.06 11502.9
April 456.12 13683.6
May 511.72 15863.3
June 520.33 15610
July 531.7 16482.8
August 468.22 14514.9
September 372.91 11187.4
October 249.57 7736.77
November 168.28 5048.54
December 103.02 3193.71
Total yearly 124791

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.42 4383.97
February 223.27 6251.43
March 384.72 11926.4
April 462.48 13874.4
May 510.83 15835.7
June 515.46 15463.7
July 528.44 16381.5
August 471.81 14626.1
September 383.63 11508.9
October 262.38 8133.81
November 182.04 5461.31
December 112.93 3500.95
Total yearly 127348

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.71 4672.05
February 234.16 6556.57
March 396.01 12276.2
April 466.31 13989.4
May 507.21 15723.5
June 508.83 15264.8
July 523.28 16221.6
August 472.87 14659
September 392.04 11761.2
October 273.48 8477.96
November 194.43 5832.83
December 121.94 3780.05
Total yearly 129215

Collingwood Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.91 4926.1
February 243.53 6818.74
March 404.88 12551.2
April 467.54 14026.3
May 501.03 15532
June 499.28 14978.5
July 515.48 15979.9
August 471.12 14604.9
September 398.11 11943.2
October 282.84 8767.9
November 205.39 6161.68
December 130 4029.85
Total yearly 130320

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -3.23% temperature and irradiance loss. This totals to about -15.41%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: