Solar Calculator Canada

Solar Power Calculator for Bracebridge, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bracebridge
  • GPS Coordinates: 45.0263889, -79.19
  • Elevation: 323 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bracebridge: 37o
  • Average yearly irradiance: 1544.65 kWh/m2
  • Average yearly power output: 129693 kWh
Sun Path Bracebridge

Average yearly irradiance delivered by the Sun in Bracebridge is 1544.65/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 129693 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.5 77.6
February 3.47 97.12
March 4.83 149.68
April 5.07 151.97
May 5.65 175.04
June 5.52 165.63
July 5.91 183.31
August 5.57 172.69
September 4.65 139.63
October 3.26 100.92
November 2.47 74.04
December 1.84 57.02
Total yearly 1544.65

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 234.06 7255.92
February 321.68 9007.03
March 430.36 13341.2
April 429.55 12886.5
May 461.93 14319.7
June 440.71 13221.3
July 468 14507.9
August 443.51 13749
September 377.21 11316.2
October 273.82 8488.34
November 214.81 6444.44
December 166.3 5155.31
Total yearly 129693

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bracebridge solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 173.31 5372.53
February 259.82 7274.97
March 383.04 11874.3
April 422.08 12662.5
May 485.03 15036
June 475.79 14273.6
July 498.55 15455
August 448.03 13889
September 350.26 10507.7
October 233.54 7239.72
November 164.14 4924.06
December 120.49 3735.12
Total yearly 122244

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.68 5879.94
February 277.1 7758.71
March 397.98 12337.3
April 427.8 12834
May 484.05 15005.7
June 471.45 14143.6
July 495.56 15362.3
August 451.19 13987
September 360 10799.9
October 245.33 7605.18
November 177.89 5336.64
December 132.71 4114.1
Total yearly 125164

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.44 6337.67
February 292.41 8187.45
March 410.42 12723.2
April 431.23 12937
May 480.53 14896.3
June 465.47 13964.2
July 490.78 15214
August 452.02 14012.7
September 367.62 11028.5
October 255.53 7921.46
November 190.26 5707.84
December 143.8 4457.94
Total yearly 127388

Bracebridge Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.58 6744.9
February 305.71 8559.89
March 420.35 13030.9
April 432.34 12970.1
May 474.62 14713.3
June 456.92 13707.5
July 483.34 14983.4
August 450.5 13965.4
September 373.09 11192.7
October 264.11 8187.55
November 201.22 6036.46
December 153.73 4765.6
Total yearly 128858

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -3.94% temperature and irradiance loss. This totals to about -16.04%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

EsterhazyPort au ChoixFort Qu'AppelleRussellRoddickton-Bide ArmLeaderArborgCanmoreEstonRoblinDavidsonGoldenOyenSt. AnthonyDrumhellerKindersleyOutlookForteauRosetownKamsackCanoraHannaWatrousWynyardLaniganMurdochville