Solar Calculator Canada

Solar Power Calculator for Sunnyside, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Sunnyside
  • GPS Coordinates: 47.8710584, -53.9124861
  • Elevation: 49 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Sunnyside: 37o
  • Average yearly irradiance: 1222.7 kWh/m2
  • Average yearly power output: 104675 kWh
Sun Path Sunnyside

Average yearly irradiance delivered by the Sun in Sunnyside is 1222.7/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 104675 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.63 50.44
February 2.28 63.82
March 3.06 94.99
April 4.24 127.2
May 4.62 143.2
June 4.84 145.31
July 4.77 147.95
August 4.44 137.75
September 3.89 116.67
October 2.87 89
November 1.96 58.78
December 1.53 47.57
Total yearly 1222.7

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 139.42 4322.07
February 194.6 5448.79
March 260.95 8089.58
April 361.36 10840.8
May 394.89 12241.7
June 413.31 12399.3
July 408.34 12658.4
August 380.63 11799.4
September 333.76 10012.9
October 247.84 7683.18
November 169.61 5088.23
December 131.95 4090.5
Total yearly 104675

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Sunnyside solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.4 3236.55
February 159.1 4454.74
March 237.67 7367.8
April 355.18 10655.3
May 410.01 12710.4
June 440.19 13205.5
July 428.89 13295.5
August 382.56 11859.5
September 309.96 9298.86
October 209.47 6493.64
November 129.58 3887.4
December 94.28 2922.58
Total yearly 99387.8

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.16 3538.98
February 169.37 4742.3
March 245.37 7606.54
April 359.68 10790.3
May 409.23 12686.2
June 436.71 13101.3
July 426.81 13231.2
August 385.18 11940.7
September 318.4 9551.94
October 220.71 6842.16
November 140.73 4222.05
December 104.6 3242.48
Total yearly 101496

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 122.93 3810.79
February 178.41 4995.38
March 251.67 7801.65
April 362.41 10872.3
May 406.8 12610.9
June 431.49 12944.8
July 423.21 13119.4
August 385.92 11963.6
September 325.03 9750.92
October 230.5 7145.39
November 150.75 4522.39
December 113.94 3532.28
Total yearly 103070

Sunnyside Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.7 4051.8
February 186.21 5213.78
March 256.54 7952.86
April 363.22 10896.5
May 403.04 12494.1
June 425.12 12753.6
July 417.69 12948.3
August 384.82 11929.5
September 329.85 9895.36
October 238.8 7402.73
November 159.6 4787.97
December 122.31 3791.59
Total yearly 104118

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.04% angle of incidence loss and -1.9% temperature and irradiance loss. This totals to about -14.39%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

LaScieMacGregorMing's BightMilestoneRiversParson's PondVauxhallRedcliffKiplingFrancisRapid CityFleur de LysStonewallStavelyHamiotaRouleauGladstoneDaniel's HarbourLac du BonnetWapellaWhitewoodNantonBroadviewRocanvilleTeulonMurdochville