Solar Calculator Canada

Solar Power Calculator for North Perth, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: North Perth
  • GPS Coordinates: 43.725, -80.9672222
  • Elevation: 378 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for North Perth: 34o
  • Average yearly irradiance: 1491.07 kWh/m2
  • Average yearly power output: 123723 kWh
Sun Path North Perth

Average yearly irradiance delivered by the Sun in North Perth is 1491.07/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 123723 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.85 57.36
February 2.33 65.37
March 4.03 124.9
April 5.11 153.17
May 5.78 179.21
June 6.02 180.61
July 6.14 190.22
August 5.73 177.72
September 4.8 143.88
October 3.31 102.57
November 2.42 72.69
December 1.4 43.36
Total yearly 1491.07

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.73 5199.75
February 210.67 5898.63
March 353.13 10947
April 432.03 12960.8
May 473.25 14670.6
June 481.79 14453.6
July 486.21 15072.7
August 456.58 14154
September 388.57 11657
October 278.27 8626.27
November 209.53 6286.01
December 122.49 3797.08
Total yearly 123723

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

North Perth solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.29 4069.85
February 177.36 4966.18
March 322.05 9983.42
April 425.01 12750.2
May 490.88 15217.3
June 511.62 15348.7
July 511.21 15847.4
August 458.93 14226.8
September 364.52 10935.6
October 243.67 7553.88
November 167.65 5029.44
December 94.21 2920.47
Total yearly 118849

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 142.68 4422.99
February 188.11 5267.06
March 333.19 10329
April 430.08 12902.3
May 489.4 15171.4
June 506.37 15191.1
July 507.38 15728.7
August 461.75 14314.2
September 373.96 11218.9
October 255.19 7910.81
November 180.79 5423.59
December 102.95 3191.34
Total yearly 121071

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 152.9 4739.84
February 197.55 5531.41
March 342.31 10611.6
April 432.87 12986.2
May 485.44 15048.7
June 499.38 14981.5
July 501.67 15551.8
August 462.07 14324.3
September 381.23 11436.8
October 265.09 8217.86
November 192.56 5776.88
December 110.85 3436.23
Total yearly 122643

North Perth Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.93 5019.89
February 205.66 5758.49
March 349.37 10830.4
April 433.24 12997.1
May 479.17 14854.1
June 490.03 14701
July 493.93 15311.8
August 459.77 14252.7
September 386.28 11588.5
October 273.35 8473.9
November 202.94 6088.16
December 117.88 3654.28
Total yearly 123530

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.98% angle of incidence loss and -4.98% temperature and irradiance loss. This totals to about -17.02%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

GaultoisRose Blanche-Harbour Le CouPortugal Cove-St. Philip'sRencontre EastWabanaEnglish Harbour EastTorbayTerrencevilleChance CoveHarbour GraceFlatrockBeresfordSouthern HarbourPouch CoveArnold's CoveVictoriaGrand Le PierreLam�queCome By ChanceHeart's ContentSunnysideMilltown-Head of Bay d'EspoirWintertonHant's HarbourOld PerlicanMurdochville