Solar Calculator Canada

Solar Power Calculator for Stratford, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Stratford
  • GPS Coordinates: 43.3725, -80.9763889
  • Elevation: 367 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Stratford: 34o
  • Average yearly irradiance: 1539.34 kWh/m2
  • Average yearly power output: 128315 kWh
Sun Path Stratford

Average yearly irradiance delivered by the Sun in Stratford is 1539.34/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 128315 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.06 63.88
February 2.67 74.87
March 4.21 130.46
April 5.22 156.66
May 5.78 179.25
June 6.05 181.4
July 6.13 189.97
August 5.77 178.78
September 4.92 147.46
October 3.48 107.97
November 2.6 77.92
December 1.64 50.72
Total yearly 1539.34

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 188.35 5838.89
February 243.52 6818.63
March 370.37 11481.5
April 442.9 13286.9
May 474.17 14699.2
June 484.85 14545.6
July 486.03 15067
August 459.73 14251.7
September 398.64 11959.2
October 293.8 9107.67
November 225.74 6772.11
December 144.72 4486.36
Total yearly 128315

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Stratford solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.44 4570.5
February 205.22 5746.25
March 337.88 10474.2
April 436.09 13082.6
May 493.52 15299.1
June 516.76 15502.8
July 512.79 15896.4
August 463.39 14365.1
September 373.53 11205.8
October 256.09 7938.88
November 179.29 5378.7
December 110.79 3434.63
Total yearly 122895

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 159.94 4958.22
February 217.33 6085.3
March 349.38 10830.6
April 441.29 13238.6
May 491.94 15250
June 511.4 15342.1
July 508.87 15775
August 466.13 14449.9
September 383.3 11499
October 268.37 8319.4
November 193.51 5805.38
December 121.07 3753.15
Total yearly 125307

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.16 5306.06
February 227.96 6382.9
March 358.75 11121.3
April 444.13 13323.9
May 487.82 15122.3
June 504.32 15129.7
July 503.15 15597.6
August 466.27 14454.3
September 390.81 11724.4
October 278.94 8647.04
November 206.26 6187.93
December 130.35 4040.99
Total yearly 127039

Stratford Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.08 5613.39
February 237.08 6638.13
March 365.98 11345.5
April 444.48 13334.5
May 481.45 14925
June 494.86 14845.7
July 495.17 15350.4
August 463.78 14377.2
September 396.04 11881.2
October 287.76 8920.58
November 217.51 6525.17
December 138.62 4297.27
Total yearly 128054

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.94% angle of incidence loss and -4.58% temperature and irradiance loss. This totals to about -16.64%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: