The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Thorold
  • GPS Coordinates: 43.0722222, -79.2233333
  • Elevation: 177 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Thorold: 34o
  • Average yearly irradiance: 1552.75 kWh/m2
  • Average yearly power output: 130069 kWh
Sun Path Thorold

Average yearly irradiance delivered by the Sun in Thorold is 1552.75/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 130069 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.11 65.47
February 2.75 77.14
March 4.25 131.61
April 5.2 155.86
May 5.95 184.44
June 6 180.06
July 6.09 188.91
August 5.83 180.85
September 4.85 145.62
October 3.37 104.48
November 2.77 83.03
December 1.78 55.28
Total yearly 1552.75

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 192.4 5964.28
February 251.25 7035.02
March 376.61 11674.9
April 444.14 13324.2
May 490.85 15216.2
June 483.82 14514.6
July 484.81 15029.1
August 466.2 14452.3
September 395.43 11863
October 284.59 8822.23
November 242.35 7270.64
December 158.15 4902.8
Total yearly 130069

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Thorold solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 152.34 4722.58
February 214.74 6012.61
March 344.65 10684.2
April 437.1 13113
May 510.93 15838.9
June 515.4 15462.1
July 511.37 15852.6
August 469.07 14541.1
September 370.64 11119.1
October 248.95 7717.42
November 192.18 5765.36
December 121.6 3769.69
Total yearly 124599

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.57 5101.69
February 226.36 6338.08
March 356 11036
April 442.33 13270
May 509.4 15791.5
June 510.68 15320.5
July 507.81 15742.2
August 471.92 14629.5
September 380.3 11409.1
October 260.56 8077.27
November 207.49 6224.63
December 132.63 4111.53
Total yearly 127052

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.55 5441.96
February 236.51 6622.35
March 365.22 11322
April 445.2 13356.1
May 505.21 15661.6
June 503.6 15108
July 502.08 15564.5
August 472.35 14642.8
September 387.72 11631.7
October 270.53 8386.44
November 221.23 6636.93
December 142.62 4421.27
Total yearly 128796

Thorold Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.24 5742.41
February 245.16 6864.38
March 372.29 11541.1
April 445.64 13369.3
May 498.46 15452.2
June 493.84 14815.1
July 493.88 15310.4
August 470.13 14573.9
September 392.87 11786
October 278.83 8643.7
November 233.36 7000.84
December 151.54 4697.63
Total yearly 129797

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.86% angle of incidence loss and -4.18% temperature and irradiance loss. This totals to about -16.23%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville