The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Candiac
  • GPS Coordinates: 45.394849, -73.519149
  • Elevation: 20 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Candiac: 39o
  • Average yearly irradiance: 1568.91 kWh/m2
  • Average yearly power output: 132183 kWh
Sun Path Candiac

Average yearly irradiance delivered by the Sun in Candiac is 1568.91/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 132183 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.73 84.75
February 3.51 98.25
March 4.5 139.38
April 5.1 153.11
May 5.59 173.3
June 5.48 164.46
July 5.9 182.93
August 5.74 177.84
September 4.83 144.93
October 3.37 104.49
November 2.83 85.03
December 1.95 60.45
Total yearly 1568.91

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 256.84 7961.96
February 326.56 9143.72
March 401.63 12450.6
April 434.41 13032.4
May 457.86 14193.7
June 438.58 13157.5
July 466.87 14473
August 457.72 14189.3
September 392.02 11760.6
October 284.92 8832.62
November 249.31 7479.17
December 177.68 5508.21
Total yearly 132183

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Candiac solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.25 5680.74
February 259.24 7258.6
March 356.58 11054.1
April 425.66 12769.9
May 481.15 14915.7
June 475.46 14263.9
July 500.17 15505.2
August 461.05 14292.5
September 362.09 10862.7
October 238.72 7400.38
November 185.49 5564.82
December 124.47 3858.44
Total yearly 123427

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 202.04 6263.26
February 277.25 7763.02
March 370.41 11482.8
April 431.82 12954.5
May 480.76 14903.5
June 472.12 14163.7
July 497.85 15433.3
August 465.01 14415.3
September 372.69 11180.6
October 251.61 7799.95
November 201.95 6058.61
December 137.93 4275.7
Total yearly 126694

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.09 6791.86
February 293.23 8210.37
March 381.94 11840.2
April 435.63 13068.8
May 477.87 14814
June 466.24 13987.3
July 493 15283
August 466.49 14461.2
September 381.05 11431.5
October 262.83 8147.74
November 216.78 6503.51
December 150.17 4655.22
Total yearly 129195

Candiac Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 234.35 7264.93
February 307.13 8599.62
March 391.14 12125.2
April 437.08 13112.3
May 472.57 14649.7
June 458.1 13743.1
July 485.67 15055.8
August 465.49 14430.2
September 387.15 11614.6
October 272.34 8442.6
November 229.95 6898.41
December 161.16 4995.93
Total yearly 130932

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -3.74% temperature and irradiance loss. This totals to about -15.75%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: