Solar Calculator Canada

Solar Power Calculator for Chute-aux-Outardes, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chute-aux-Outardes
  • GPS Coordinates: 49.1166667, -68.4
  • Elevation: 28 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chute-aux-Outardes: 41o
  • Average yearly irradiance: 1432.29 kWh/m2
  • Average yearly power output: 123477 kWh
Sun Path Chute-aux-Outardes

Average yearly irradiance delivered by the Sun in Chute-aux-Outardes is 1432.29/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 123477 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.15 66.7
February 3.26 91.26
March 4.27 132.51
April 4.87 146.02
May 5.29 163.88
June 5.34 160.27
July 5.47 169.54
August 5.05 156.42
September 4.31 129.39
October 3.12 96.84
November 2.21 66.26
December 1.72 53.21
Total yearly 1432.29

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.45 6400.07
February 308.41 8635.4
March 390.44 12103.5
April 426.4 12791.9
May 446.8 13850.9
June 438.69 13160.7
July 443.34 13743.4
August 411.41 12753.8
September 359.83 10794.9
October 269.86 8365.51
November 197.26 5917.79
December 159.98 4959.33
Total yearly 123477

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chute-aux-Outardes solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.38 4351.68
February 234.14 6555.9
March 338.09 10480.7
April 413.56 12406.8
May 467.52 14493
June 473.94 14218.1
July 471.23 14608.1
August 411.39 12753
September 325.41 9762.42
October 217.62 6746.26
November 139.65 4189.4
December 104.17 3229.32
Total yearly 113795

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 156.05 4837.42
February 252.57 7072.03
March 352.98 10942.4
April 420.99 12629.6
May 468.17 14513.3
June 471.41 14142.2
July 470.33 14580.2
August 416.08 12898.5
September 336.42 10092.7
October 231.12 7164.63
November 153.47 4604.2
December 117.25 3634.89
Total yearly 117112

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.35 5280.74
February 269.07 7533.82
March 365.61 11333.9
April 426.16 12784.8
May 466.68 14467
June 466.73 14002
July 467.39 14489.2
August 418.57 12975.8
September 345.38 10361.3
October 243.01 7533.32
November 166.03 4980.82
December 129.25 4006.68
Total yearly 119749

Chute-aux-Outardes Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.23 5680.15
February 283.58 7940.16
March 375.95 11654.3
April 428.83 12865
May 463.32 14363
June 460.18 13805.5
July 462.42 14334.9
August 418.83 12983.8
September 352.25 10567.5
October 253.26 7851.17
November 177.27 5318.06
December 140.11 4343.33
Total yearly 121707

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -1.45% temperature and irradiance loss. This totals to about -13.79%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

EngleeRegina BeachBassanoCentral ButteBalcarresKyleLangenburgChurchbridgeConcheBredenburySoutheyCuparChestermereSaltcoatsStrathmoreCraikSte. Rose du LacStrasbourgGilbert PlainsMain BrookItunaGrandviewElroseCochraneEatoniaMurdochville