Solar Calculator Canada

Solar Power Calculator for Ferland, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ferland
  • GPS Coordinates: 48.181389, -70.846111
  • Elevation: 250 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ferland: 41o
  • Average yearly irradiance: 1399.64 kWh/m2
  • Average yearly power output: 120021 kWh
Sun Path Ferland

Average yearly irradiance delivered by the Sun in Ferland is 1399.64/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 120021 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.74 84.99
February 3.67 102.88
March 4.4 136.4
April 4.67 140.16
May 5.08 157.35
June 5.15 154.41
July 5.18 160.62
August 4.72 146.28
September 4.05 121.61
October 2.78 86.16
November 1.88 56.25
December 1.69 52.52
Total yearly 1399.64

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 264.85 8210.43
February 349.34 9781.52
March 401.83 12456.6
April 406.27 12188.1
May 422.59 13100.2
June 415.8 12474
July 414.75 12857.1
August 380.45 11793.9
September 332.66 9979.69
October 236.73 7338.71
November 165.41 4962.32
December 157.37 4878.52
Total yearly 120021

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ferland solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.14 5615.23
February 266.79 7470.24
March 350.93 10878.9
April 397.71 11931.2
May 444.05 13765.6
June 451.75 13552.5
July 443.43 13746.3
August 385.04 11936.3
September 305.78 9173.47
October 197.46 6121.4
November 122.36 3670.92
December 106.93 3314.89
Total yearly 111177

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 201.42 6243.89
February 287.56 8051.57
March 365.72 11337.4
April 403.79 12113.7
May 444.07 13766.3
June 448.48 13454.4
July 441.98 13701.5
August 388.09 12030.8
September 314.95 9448.57
October 208.03 6448.88
November 133.04 3991.24
December 119.13 3692.88
Total yearly 114281

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.82 6814.5
February 306.11 8571.03
March 378.23 11725
April 407.73 12231.8
May 442.18 13707.4
June 443.74 13312.3
July 438.51 13593.8
August 389.17 12064.4
September 322.26 9667.86
October 217.23 6734.22
November 142.67 4280.01
December 130.22 4036.71
Total yearly 116739

Ferland Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 236.33 7326.3
February 322.41 9027.47
March 388.4 12040.5
April 409.53 12286
May 437.96 13576.7
June 436.63 13098.8
July 432.78 13416
August 388.3 12037.2
September 327.69 9830.63
October 225.05 6976.47
November 151.21 4536.35
December 140.18 4345.63
Total yearly 118498

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.89% angle of incidence loss and -1.89% temperature and irradiance loss. This totals to about -14.25%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

NetherhillMarengoBroderickRamaTessierZelmaArranStenenPlunkettBradwellClavetKinleyMeachamTramping LakeFosstonPrimateSpaldingPilgerAlvenaPleasantdaleRuddellDenholmRichardSpeersKrydorMurdochville