Solar Calculator Canada

Solar Power Calculator for Broderick, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Broderick
  • GPS Coordinates: 51.489117, -106.917819
  • Elevation: 553 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Broderick: 43o
  • Average yearly irradiance: 1504.99 kWh/m2
  • Average yearly power output: 127659 kWh
Sun Path Broderick

Average yearly irradiance delivered by the Sun in Broderick is 1504.99/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 127659 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.79 55.47
February 2.64 73.85
March 3.63 112.45
April 5.34 160.14
May 5.77 178.93
June 5.61 168.23
July 6.43 199.45
August 5.81 180.18
September 4.98 149.36
October 3.67 113.85
November 2.1 62.89
December 1.62 50.18
Total yearly 1504.99

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.37 5281.49
February 248.18 6949.05
March 325.98 10105.5
April 460.19 13805.6
May 481.01 14911.4
June 453.17 13595.1
July 513.37 15914.3
August 467.27 14485.3
September 411.71 12351.4
October 317.27 9835.37
November 188.98 5669.39
December 153.41 4755.61
Total yearly 127659

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Broderick solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.68 3245.04
February 175.67 4918.76
March 272.47 8446.64
April 435.96 13078.8
May 499.04 15470.1
June 490.88 14726.4
July 544.74 16887
August 459.87 14256
September 358.74 10762.2
October 240.73 7462.7
November 124.89 3746.74
December 88.67 2748.68
Total yearly 115749

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.33 3699.16
February 192.78 5397.96
March 286.8 8890.77
April 446.14 13384.1
May 501.75 15554.3
June 489.4 14682
July 545.28 16903.8
August 467.18 14482.6
September 373.88 11216.3
October 259.12 8032.81
November 139.39 4181.79
December 102.99 3192.71
Total yearly 119618

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.76 4115.55
February 208.22 5830.15
March 299.15 9273.73
April 453.75 13612.5
May 501.67 15551.6
June 485.66 14569.8
July 543.41 16845.7
August 471.79 14625.4
September 386.58 11597.5
October 275.55 8542.18
November 152.63 4578.88
December 116.16 3601.06
Total yearly 122744

Broderick Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.94 4493.09
February 221.95 6214.6
March 309.51 9594.71
April 458.78 13763.3
May 498.87 15465
June 479.27 14378.1
July 538.56 16695.5
August 473.77 14687
September 396.82 11904.7
October 289.98 8989.33
November 164.56 4936.78
December 128.15 3972.53
Total yearly 125095

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -3.13% temperature and irradiance loss. This totals to about -15.18%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-PascalClermontBonaventureCarleton-sur-MerGrande-Rivi�reDesbiensM�tabetchouan-Lac-�-la-CroixLangfordDuparquetSaint-Honor�M�tis-sur-MerMacamicNormandinWhite RockRosslandDeltaGreenwoodLangleySurreySainte-Anne-des-MontsRichmondNew WestminsterMaple RidgeBurnabyPort CoquitlamMurdochville