Solar Calculator Canada

Solar Power Calculator for Pleasantdale, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Pleasantdale
  • GPS Coordinates: 52.5764972, -104.5066167
  • Elevation: 538 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Pleasantdale: 43o
  • Average yearly irradiance: 1485 kWh/m2
  • Average yearly power output: 127159 kWh
Sun Path Pleasantdale

Average yearly irradiance delivered by the Sun in Pleasantdale is 1485/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 127159 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.73 53.52
February 2.62 73.36
March 3.62 112.1
April 5.28 158.29
May 5.95 184.47
June 5.63 168.99
July 6.17 191.36
August 5.83 180.63
September 4.89 146.62
October 3.58 110.86
November 1.91 57.25
December 1.53 47.54
Total yearly 1485

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.67 5197.65
February 250.69 7019.24
March 329.43 10212.3
April 457.59 13727.8
May 498.72 15460.4
June 459.14 13774.1
July 497.62 15426.3
August 472.7 14653.6
September 408.03 12240.9
October 311.64 9660.77
November 174.43 5232.91
December 146.88 4553.4
Total yearly 127159

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Pleasantdale solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 102.1 3165.03
February 174.16 4876.46
March 271.01 8401.37
April 431.9 12957.1
May 518.36 16069.1
June 497.89 14936.8
July 527.49 16352.2
August 463.07 14355.3
September 353.26 10597.8
October 232.12 7195.72
November 112.5 3375.05
December 84.65 2624.15
Total yearly 114906

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 116.51 3611.7
February 191.44 5360.38
March 285.89 8862.74
April 442.48 13274.5
May 521.58 16169
June 496.33 14889.9
July 528.48 16383
August 470.95 14599.3
September 368.69 11060.8
October 250.68 7771.15
November 126.15 3784.49
December 98.16 3043.1
Total yearly 118810

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 129.69 4020.52
February 207.04 5797.19
March 298.78 9262.32
April 450.49 13514.7
May 521.93 16179.7
June 493.51 14805.4
July 527.1 16340
August 476.1 14759.1
September 381.71 11451.4
October 267.31 8286.69
November 138.62 4158.74
December 110.61 3428.99
Total yearly 122005

Pleasantdale Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.64 4390.72
February 220.93 6186.16
March 309.66 9599.35
April 455.9 13676.9
May 519.33 16099.3
June 487.35 14620.6
July 522.42 16195
August 478.57 14835.6
September 392.27 11768.2
October 281.96 8740.78
November 149.88 4496.55
December 121.95 3780.56
Total yearly 124390

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.19% temperature and irradiance loss. This totals to about -14.37%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.