The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Fermont
  • GPS Coordinates: 52.796933, -67.091008
  • Elevation: 605 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Fermont: 45o
  • Average yearly irradiance: 1303.9 kWh/m2
  • Average yearly power output: 116144 kWh
Sun Path Fermont

Average yearly irradiance delivered by the Sun in Fermont is 1303.9/kWh/m2 at the optimal panel slope of 45o. After taking all losses into account, you can expect about 116144 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 45o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.24 69.38
February 3.6 100.87
March 4.59 142.23
April 4.64 139.31
May 4.76 147.71
June 5.13 153.81
July 4.66 144.31
August 4.14 128.27
September 3.52 105.66
October 2.46 76.35
November 1.48 44.52
December 1.66 51.49
Total yearly 1303.9

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.6 6962.54
February 355.01 9940.22
March 438.19 13583.9
April 420.79 12623.7
May 413.84 12829
June 427.7 12831
July 383.14 11877.3
August 342.69 10623.5
September 301.17 9035.1
October 216.72 6718.44
November 135.75 4072.48
December 162.82 5047.37
Total yearly 116144

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Fermont solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.4 4197.33
February 246.26 6895.4
March 360.85 11186.4
April 404.18 12125.5
May 437.62 13566.4
June 467.59 14027.7
July 414.02 12834.6
August 346.57 10743.8
September 270.98 8129.4
October 170.98 5300.38
November 91.55 2746.58
December 94.1 2917.22
Total yearly 104670

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.46 4788.33
February 270.48 7573.43
March 380.45 11793.9
April 412.8 12384.1
May 438.39 13590.1
June 465.68 13970.4
July 413.04 12804.2
August 350.19 10855.9
September 280.28 8408.26
October 181.86 5637.7
November 101.2 3036.1
December 108.67 3368.92
Total yearly 108211

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.95 5330.42
February 292.37 8186.34
March 397.44 12320.7
April 419.15 12574.6
May 437.21 13553.6
June 461.65 13849.4
July 410.26 12717.9
August 352.19 10918
September 287.9 8637.1
October 191.51 5936.68
November 110.01 3300.17
December 122.08 3784.36
Total yearly 111109

Fermont Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.81 5822.05
February 311.89 8732.83
March 411.79 12765.4
April 423.05 12691.5
May 434.24 13461.4
June 455.61 13668.2
July 405.81 12580.2
August 352.46 10926.1
September 293.83 8814.93
October 199.87 6196.09
November 117.92 3537.59
December 134.27 4162.31
Total yearly 113359

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.93% angle of incidence loss and 1.96% temperature and irradiance loss. This totals to about -10.93%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: