Solar Calculator Canada

Solar Power Calculator for Gatineau, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Gatineau
  • GPS Coordinates: 45.427929, -75.710938
  • Elevation: 59 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Gatineau: 39o
  • Average yearly irradiance: 1567.12 kWh/m2
  • Average yearly power output: 131386 kWh
Sun Path Gatineau

Average yearly irradiance delivered by the Sun in Gatineau is 1567.12/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 131386 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.75 85.39
February 3.57 99.83
March 4.63 143.54
April 5.12 153.51
May 5.53 171.58
June 5.53 166.04
July 5.86 181.62
August 5.6 173.55
September 4.83 144.78
October 3.41 105.61
November 2.69 80.79
December 1.96 60.87
Total yearly 1567.12

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 257.7 7988.6
February 330.3 9248.36
March 413.75 12826.3
April 433.53 13005.9
May 450.33 13960.2
June 439.59 13187.7
July 460.22 14266.7
August 443.6 13751.6
September 390.15 11704.5
October 286.36 8877.25
November 235.12 7053.54
December 177.91 5515.18
Total yearly 131386

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Gatineau solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.8 5728.73
February 262.67 7354.86
March 367.32 11387
April 425.28 12758.3
May 474.31 14703.5
June 477.9 14337
July 493.32 15293
August 447.94 13886.2
September 359.64 10789.1
October 240.16 7445.09
November 176.8 5304.01
December 126.11 3909.35
Total yearly 122896

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.7 6314.69
February 280.88 7864.64
March 381.54 11827.8
April 431.33 12939.8
May 473.5 14678.4
June 474.21 14226.4
July 490.97 15220.1
August 451.41 13993.7
September 370.29 11108.8
October 253.12 7846.63
November 192.01 5760.4
December 139.34 4319.66
Total yearly 126101

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 220.81 6845.08
February 297.01 8316.33
March 393.39 12195
April 435.03 13050.9
May 470.31 14579.6
June 468 14040.1
July 485.95 15064.4
August 452.49 14027.2
September 378.73 11361.8
October 264.39 8196.02
November 205.69 6170.79
December 151.34 4691.55
Total yearly 128539

Gatineau Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 236.09 7318.76
February 311.04 8709.03
March 402.83 12487.8
April 436.38 13091.4
May 464.78 14408
June 459.52 13785.7
July 478.52 14834
August 451.19 13986.8
September 384.91 11547.2
October 273.94 8492.16
November 217.81 6534.22
December 162.07 5024.31
Total yearly 130220

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -4.2% temperature and irradiance loss. This totals to about -16.16%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: