Solar Calculator Canada

Solar Power Calculator for Granby, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Granby
  • GPS Coordinates: 45.398555, -72.722249
  • Elevation: 115 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Granby: 38o
  • Average yearly irradiance: 1487.59 kWh/m2
  • Average yearly power output: 124541 kWh
Sun Path Granby

Average yearly irradiance delivered by the Sun in Granby is 1487.59/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 124541 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.6 80.57
February 3.17 88.87
March 4.16 128.95
April 4.82 144.54
May 5.26 163.19
June 5.33 159.99
July 5.75 178.29
August 5.42 168.1
September 4.65 139.4
October 3.22 99.93
November 2.67 80.1
December 1.79 55.64
Total yearly 1487.59

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 242.6 7520.67
February 292.42 8187.73
March 368.32 11418
April 407.1 12213
May 429.19 13304.9
June 425.31 12759.2
July 453.88 14070.4
August 431.35 13371.9
September 375.47 11264.1
October 270.95 8399.37
November 233.43 7003.03
December 162.22 5028.92
Total yearly 124541

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Granby solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.05 5426.48
February 236.12 6611.23
March 329.62 10218.3
April 400.34 12010.2
May 450.63 13969.6
June 460.02 13800.6
July 484.89 15031.6
August 435.49 13500.2
September 347.85 10435.4
October 228.45 7081.97
November 175.45 5263.64
December 115.22 3571.71
Total yearly 116921

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 192.74 5975.01
February 251.62 7045.36
March 341.83 10596.7
April 405.69 12170.6
May 449.95 13948.3
June 456.51 13695.2
July 482.5 14957.6
August 438.71 13599.9
September 357.74 10732.2
October 240.55 7456.95
November 190.8 5724.04
December 127.45 3951.03
Total yearly 119853

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 208.77 6471.77
February 265.31 7428.64
March 351.94 10910.1
April 408.86 12265.8
May 446.96 13855.8
June 450.59 13517.7
July 477.65 14807.3
August 439.65 13629.2
September 365.52 10965.5
October 251.06 7782.78
November 204.6 6137.95
December 138.56 4295.36
Total yearly 122068

Granby Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 223.08 6915.48
February 277.15 7760.31
March 359.92 11157.5
April 409.85 12295.5
May 441.79 13695.6
June 442.54 13276.2
July 470.45 14583.9
August 438.31 13587.7
September 371.17 11135
October 259.95 8058.43
November 216.82 6504.56
December 148.51 4603.8
Total yearly 123574

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -4.27% temperature and irradiance loss. This totals to about -16.28%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Clark's HarbourGoderichShelburneCobourgNewmarketBridgewaterLunenburgCollingwoodDigbyAnnapolis RoyalMidlandGravenhurstPerthMiddletonBracebridgeKentvilleStewiackeSt. StephenHuntsvilleParry SoundTruroArnpriorRenfrewHamptonNew GlasgowMurdochville