Solar Calculator Canada

Solar Power Calculator for Pincourt, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Pincourt
  • GPS Coordinates: 45.357091, -73.982202
  • Elevation: 22 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Pincourt: 38o
  • Average yearly irradiance: 1538.96 kWh/m2
  • Average yearly power output: 129311 kWh
Sun Path Pincourt

Average yearly irradiance delivered by the Sun in Pincourt is 1538.96/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 129311 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.58 79.84
February 3.21 89.81
March 4.36 135.09
April 4.99 149.59
May 5.53 171.52
June 5.5 165.08
July 5.87 181.84
August 5.73 177.62
September 4.79 143.62
October 3.31 102.63
November 2.81 84.25
December 1.87 58.08
Total yearly 1538.96

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 241.04 7472.37
February 296.56 8303.6
March 388.27 12036.4
April 424.18 12725.5
May 452.92 14040.4
June 439.79 13193.8
July 463.82 14378.5
August 457.16 14172.1
September 388.13 11643.9
October 279.45 8663.02
November 246.76 7402.76
December 170.27 5278.38
Total yearly 129311

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Pincourt solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.91 5360.25
February 237.07 6637.94
March 345.59 10713.4
April 416.75 12502.6
May 475.44 14738.5
June 475.86 14275.9
July 495.96 15374.9
August 460.35 14270.9
September 359.14 10774.2
October 235 7284.88
November 185.01 5550.18
December 120.02 3720.65
Total yearly 121204

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.62 5909.09
February 253.29 7092.05
March 358.92 11126.4
April 422.41 12672.2
May 474.85 14720.3
June 472.42 14172.5
July 493.54 15299.8
August 464.18 14389.6
September 369.48 11084.3
October 247.55 7674.03
November 201.21 6036.44
December 132.96 4121.68
Total yearly 124298

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.66 6406.49
February 267.64 7493.84
March 370 11470
April 425.8 12774.1
May 471.85 14627.3
June 466.48 13994.5
July 488.65 15148
August 465.55 14432.1
September 377.61 11328.4
October 258.47 8012.65
November 215.81 6474.2
December 144.72 4486.26
Total yearly 126648

Pincourt Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 221 6851.13
February 280.09 7842.49
March 378.81 11743.1
April 426.92 12807.7
May 466.49 14461.1
June 458.31 13749.2
July 481.32 14921
August 464.45 14398
September 383.52 11505.7
October 267.73 8299.56
November 228.75 6862.43
December 155.27 4813.4
Total yearly 128255

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -3.96% temperature and irradiance loss. This totals to about -15.98%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Pilley's IslandPort AnsonBrightonMiles CoveLittle BayBeachsideLittle Bay IslandsCrow HeadSally's CoveBurlingtonWestportNippers HarbourTilt CoveBrent's CoveWoodstockPacquetCoachman's CoveFlemingBellburnsBird CoveAnchor PointL'Anse-au-ClairWest St. ModesteOslerSt. LewisMurdochville