Solar Calculator Canada

Solar Power Calculator for Pointe-Lebel, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Pointe-Lebel
  • GPS Coordinates: 49.159045, -68.197021
  • Elevation: 10 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Pointe-Lebel: 37o
  • Average yearly irradiance: 1365.15 kWh/m2
  • Average yearly power output: 116949 kWh
Sun Path Pointe-Lebel

Average yearly irradiance delivered by the Sun in Pointe-Lebel is 1365.15/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 116949 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.32 41.02
February 2.49 69.81
March 3.89 120.73
April 4.81 144.25
May 5.42 167.9
June 5.51 165.18
July 5.68 175.98
August 5.24 162.52
September 4.34 130.25
October 3.07 95.2
November 1.92 57.6
December 1.12 34.72
Total yearly 1365.15

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.86 3498.69
February 214.99 6019.84
March 333.39 10335.2
April 410.52 12315.5
May 462.39 14333.9
June 470.36 14110.8
July 485.99 15065.8
August 449.74 13941.9
September 372.79 11183.8
October 265.58 8232.93
November 166.2 4986.11
December 94.33 2924.14
Total yearly 116949

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Pointe-Lebel solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.57 2714.57
February 176.3 4936.43
March 297.54 9223.83
April 397.88 11936.3
May 475.35 14736
June 496.4 14891.9
July 506.24 15693.4
August 445.22 13801.8
September 340.08 10202.3
October 220.57 6837.81
November 125.25 3757.63
December 69.68 2159.94
Total yearly 110892

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 94.58 2931.83
February 187.39 5246.89
March 308.88 9575.27
April 404.42 12132.6
May 475.84 14751.1
June 493.75 14812.6
July 505.27 15663.4
August 450.16 13954.9
September 351.13 10533.8
October 233.63 7242.63
November 136.55 4096.36
December 76.42 2369.17
Total yearly 113311

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 100.88 3127.2
February 197.17 5520.64
March 318.35 9868.8
April 408.87 12266.2
May 474.26 14702
June 488.96 14668.9
July 502.17 15567.3
August 452.81 14037.2
September 360.07 10802.2
October 245.08 7597.39
November 146.72 4401.64
December 82.54 2558.7
Total yearly 115118

Pointe-Lebel Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.45 3300.06
February 205.62 5757.31
March 325.94 10104.2
April 411.06 12331.8
May 470.84 14596
June 482.22 14466.5
July 497.01 15407.4
August 453.1 14046.1
September 366.91 11007.2
October 254.89 7901.53
November 155.76 4672.83
December 88 2727.93
Total yearly 116319

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.86% angle of incidence loss and -2.02% temperature and irradiance loss. This totals to about -14.33%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: