Solar Calculator Canada

Solar Power Calculator for Stoneham, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Stoneham
  • GPS Coordinates: 47.000833, -71.363333
  • Elevation: 173 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Stoneham: 40o
  • Average yearly irradiance: 1453.82 kWh/m2
  • Average yearly power output: 123741 kWh
Sun Path Stoneham

Average yearly irradiance delivered by the Sun in Stoneham is 1453.82/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 123741 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.87 89.09
February 3.58 100.25
March 4.52 140.18
April 4.7 140.97
May 5.13 159.16
June 5.14 154.29
July 5.35 165.77
August 4.94 153.21
September 4.28 128.25
October 3.04 94.1
November 2.24 67.34
December 1.97 61.22
Total yearly 1453.82

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 273.4 8475.28
February 335.96 9406.8
March 407.71 12639
April 403.04 12091.3
May 423.95 13142.4
June 413.35 12400.4
July 425.63 13194.6
August 396.37 12287.6
September 349.48 10484.5
October 258.37 8009.39
November 198.18 5945.53
December 182.72 5664.18
Total yearly 123741

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Stoneham solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.34 5900.51
February 262.55 7351.28
March 358.25 11105.7
April 395.48 11864.3
May 446.56 13843.2
June 450.54 13516.2
July 457.03 14167.9
August 401.32 12440.8
September 321.98 9659.41
October 215.09 6667.65
November 146.51 4395.3
December 124.84 3870.04
Total yearly 114782

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 210.91 6538.33
February 281.43 7880.14
March 372.83 11557.6
April 401.24 12037.2
May 446.22 13832.7
June 446.86 13405.8
July 455.07 14107.1
August 404.37 12535.6
September 331.57 9947.17
October 226.89 7033.59
November 159.5 4784.94
December 139.1 4312.24
Total yearly 117972

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 229.54 7115.85
February 298.21 8350.02
March 385.07 11937.3
April 404.85 12145.7
May 443.8 13757.8
June 441.65 13249.5
July 450.78 13974.2
August 405.36 12566.1
September 339.18 10175.5
October 237.18 7352.59
November 171.18 5135.33
December 152.05 4713.57
Total yearly 120473

Stoneham Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 246.21 7632.48
February 312.86 8760.06
March 394.96 12243.7
April 406.43 12193
May 439.12 13612.8
June 434.03 13021
July 444.25 13771.9
August 404.29 12532.8
September 344.79 10343.8
October 245.93 7623.73
November 181.53 5445.85
December 163.66 5073.54
Total yearly 122255

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -2.68% temperature and irradiance loss. This totals to about -14.89%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

NetherhillMarengoBroderickRamaTessierZelmaArranStenenPlunkettBradwellClavetKinleyMeachamTramping LakeFosstonPrimateSpaldingPilgerAlvenaPleasantdaleRuddellDenholmRichardSpeersKrydorMurdochville