Solar Calculator Canada

Solar Power Calculator for Bjorkdale, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bjorkdale
  • GPS Coordinates: 52.709075, -103.6448083
  • Elevation: 486 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bjorkdale: 43o
  • Average yearly irradiance: 1461.91 kWh/m2
  • Average yearly power output: 124540 kWh
Sun Path Bjorkdale

Average yearly irradiance delivered by the Sun in Bjorkdale is 1461.91/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 124540 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.75 54.38
February 2.72 76.05
March 3.89 120.49
April 5.32 159.49
May 5.8 179.85
June 5.49 164.62
July 6.06 187.74
August 5.65 175.28
September 4.58 137.5
October 3.33 103.25
November 1.84 55.34
December 1.55 47.91
Total yearly 1461.91

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.92 5236.47
February 258.31 7232.57
March 351.55 10898
April 458.45 13753.5
May 482.93 14970.9
June 444.84 13345.3
July 485.18 15040.7
August 456.28 14144.8
September 380.23 11407
October 288.31 8937.54
November 167.28 5018.46
December 146.93 4554.74
Total yearly 124540

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bjorkdale solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.76 3216.48
February 184.5 5166.09
March 290.61 9008.98
April 432.63 12979
May 502.75 15585.2
June 482.29 14468.8
July 513.96 15932.9
August 448.2 13894.2
September 331.7 9950.97
October 217.28 6735.75
November 108.37 3251.02
December 85.25 2642.69
Total yearly 112832

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.04 3659.3
February 201.43 5639.92
March 306.19 9491.92
April 443.18 13295.3
May 505.52 15671.2
June 480.76 14422.8
July 514.91 15962.3
August 455.36 14116.1
September 345.49 10364.7
October 233.96 7252.7
November 121.41 3642.22
December 98.68 3059.01
Total yearly 116577

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.11 4064.46
February 216.67 6066.68
March 319.65 9909.1
April 451.15 13534.5
May 505.72 15677.4
June 477.69 14330.8
July 513.45 15917
August 459.98 14259.3
September 357.07 10712.2
October 248.87 7714.82
November 133.31 3999.35
December 111.03 3441.79
Total yearly 119628

Bjorkdale Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 142.94 4431.11
February 230.2 6445.66
March 330.96 10259.8
April 456.54 13696.3
May 503.06 15595
June 471.66 14149.7
July 508.86 15774.6
August 462.05 14323.6
September 366.42 10992.6
October 261.96 8120.75
November 144.04 4321.31
December 122.26 3789.91
Total yearly 121900

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -2.64% temperature and irradiance loss. This totals to about -14.81%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville