Solar Calculator Canada

Solar Power Calculator for Buchanan, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Buchanan
  • GPS Coordinates: 51.706881, -102.755903
  • Elevation: 503 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Buchanan: 43o
  • Average yearly irradiance: 1506.81 kWh/m2
  • Average yearly power output: 128873 kWh
Sun Path Buchanan

Average yearly irradiance delivered by the Sun in Buchanan is 1506.81/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 128873 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.87 58.09
February 2.82 78.83
March 3.54 109.69
April 5.42 162.63
May 5.8 179.72
June 5.71 171.31
July 6.23 193.18
August 5.84 180.99
September 4.97 148.97
October 3.64 112.86
November 2.09 62.83
December 1.54 47.7
Total yearly 1506.81

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 182.13 5646.16
February 269.57 7547.96
March 320.39 9932.16
April 468.49 14054.7
May 484.68 15025
June 464.3 13929.1
July 501.24 15538.3
August 473.05 14664.6
September 414.12 12423.7
October 317.01 9827.22
November 191.3 5739.06
December 146.63 4545.43
Total yearly 128873

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Buchanan solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.21 3447.59
February 188.42 5275.62
March 264.28 8192.65
April 443.5 13304.9
May 506.41 15698.8
June 504.62 15138.6
July 533.24 16530.4
August 466.19 14451.8
September 361.48 10844.3
October 239.66 7429.4
November 124.98 3749.39
December 86.48 2680.81
Total yearly 116744

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.83 3931.8
February 206.96 5795.01
March 278.59 8636.26
April 454.23 13626.8
May 508.67 15768.9
June 503.08 15092.5
July 534.18 16559.6
August 473.44 14676.7
September 376.66 11299.8
October 258.02 7998.74
November 139.81 4194.18
December 99.66 3089.33
Total yearly 120670

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.12 4374.73
February 223.7 6263.64
March 290.95 9019.42
April 462.29 13868.7
May 508.52 15764
June 499.28 14978.5
July 532.15 16496.7
August 478.04 14819.2
September 389.4 11682.1
October 274.44 8507.58
November 153.34 4600.08
December 111.76 3464.42
Total yearly 123839

Buchanan Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.05 4775.57
February 238.6 6680.68
March 301.34 9341.44
April 467.67 14030.1
May 505.46 15669.1
June 492.62 14778.7
July 527.05 16338.6
August 479.97 14879
September 399.67 11990
October 288.85 8954.31
November 165.53 4965.87
December 122.74 3805.08
Total yearly 126208

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.32% temperature and irradiance loss. This totals to about -14.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DorintoshGoodsoilBoyleTelkwaGranisleHazeltonHytheKinusoPouce CoupeDonnellyGirouxvilleRycroftNampaBerwynHines CreekMerrittLourdes-de-Blanc-SablonChatham-KentSt. ThomasSarniaWellandNiagara FallsWoodstockBrantfordSt. CatharinesMurdochville