Solar Calculator Canada

Solar Power Calculator for Disley, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Disley
  • GPS Coordinates: 50.6409472, -105.0493444
  • Elevation: 558 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Disley: 42o
  • Average yearly irradiance: 1514.41 kWh/m2
  • Average yearly power output: 128372 kWh
Sun Path Disley

Average yearly irradiance delivered by the Sun in Disley is 1514.41/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 128372 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.95 60.56
February 2.72 76.07
March 3.61 111.82
April 5.32 159.51
May 5.66 175.56
June 5.67 170.12
July 6.41 198.62
August 5.84 181.09
September 5.03 150.99
October 3.67 113.83
November 2.2 66.14
December 1.62 50.1
Total yearly 1514.41

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.59 5784.34
February 256.26 7175.21
March 322.78 10006.3
April 456.65 13699.6
May 470.87 14596.9
June 458.51 13755.4
July 511.42 15853.9
August 467.85 14503.3
September 416.19 12485.7
October 316.73 9818.59
November 198.65 5959.58
December 152.67 4732.86
Total yearly 128372

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Disley solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 116.75 3619.15
February 183.95 5150.57
March 272.75 8455.14
April 434.34 13030.1
May 492.16 15257
June 498.05 14941.4
July 544.84 16890.1
August 462.65 14342.3
September 365.76 10972.9
October 243.97 7563.17
November 132.99 3989.65
December 90.96 2819.79
Total yearly 117031

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.64 4111.71
February 201.03 5628.74
March 286.29 8874.92
April 444.17 13325.2
May 494.18 15319.5
June 496.57 14897.2
July 545.29 16903.9
August 469.49 14554.3
September 380.54 11416.3
October 261.74 8113.8
November 148.07 4442.18
December 104.87 3250.89
Total yearly 120839

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.15 4561.8
February 216.41 6059.58
March 297.89 9234.66
April 451.46 13543.7
May 493.35 15293.9
June 492.45 14773.6
July 542.82 16827.5
August 473.69 14684.2
September 392.88 11786.3
October 277.56 8604.28
November 161.82 4854.72
December 117.63 3646.53
Total yearly 123871

Disley Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.28 4968.65
February 230.08 6442.26
March 307.53 9533.58
April 456.16 13684.9
May 489.94 15188.2
June 485.6 14567.9
July 537.19 16652.8
August 475.24 14732.3
September 402.73 12081.8
October 291.39 9033.13
November 174.2 5225.99
December 129.22 4005.71
Total yearly 126117

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.18% temperature and irradiance loss. This totals to about -15.23%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

GracefieldBerthiervillePrincevilleDaveluyvilleBeaucevillePlessisvilleNicoletLouisevilleSaint-GabrielSaint-Joseph-de-BeauceB�cancourRivi�re-RougeShawiniganGrand SudburyGreater SudburySaint-Marc-des-Carri�resPortneufSaint-TiteSaint-BasilePont-RougeSaint-RaymondCh�teau-RicherBelleterrePoh�n�gamookMount PearlMurdochville