Solar Calculator Canada

Solar Power Calculator for Dodsland, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Dodsland
  • GPS Coordinates: 51.8013839, -108.8392556
  • Elevation: 648 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Dodsland: 43o
  • Average yearly irradiance: 1506.1 kWh/m2
  • Average yearly power output: 127746 kWh
Sun Path Dodsland

Average yearly irradiance delivered by the Sun in Dodsland is 1506.1/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 127746 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.75 54.23
February 2.54 71.1
March 3.53 109.52
April 5.17 155.15
May 5.99 185.76
June 5.62 168.48
July 6.47 200.63
August 5.95 184.42
September 5.04 151.25
October 3.73 115.76
November 2.11 63.31
December 1.5 46.48
Total yearly 1506.1

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.32 5155.97
February 238.07 6666.01
March 315.97 9795.13
April 444.9 13347
May 500.23 15507
June 455.15 13654.5
July 517.86 16053.6
August 479.96 14878.9
September 417.87 12536.1
October 323.22 10019.9
November 191.13 5733.77
December 141.88 4398.33
Total yearly 127746

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Dodsland solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 100.69 3121.35
February 166.53 4662.9
March 262.82 8147.29
April 421.71 12651.3
May 517.41 16039.7
June 492.25 14767.5
July 548.13 16991.9
August 470.58 14587.9
September 363.03 10890.8
October 244.42 7576.88
November 124.92 3747.61
December 82.4 2554.54
Total yearly 115740

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.29 3574.06
February 183.21 5129.89
March 276.86 8582.53
April 431.54 12946.2
May 520.31 16129.8
June 490.51 14715.3
July 548.71 17009.9
August 478.47 14832.7
September 378.48 11354.4
October 263.22 8159.67
November 139.81 4194.34
December 95.52 2961.13
Total yearly 119590

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.71 3989.9
February 198.27 5551.63
March 289 8958.89
April 438.92 13167.7
May 520.67 16140.9
June 486.49 14594.7
July 546.56 16943.3
August 483.79 14997.5
September 391.49 11744.7
October 280.03 8680.82
November 153.42 4602.59
December 107.6 3335.51
Total yearly 122708

Dodsland Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.89 4367.6
February 211.69 5927.42
March 299.21 9275.51
April 443.82 13314.7
May 518.13 16062
June 480.78 14423.3
July 542.33 16812.1
August 486.36 15077.2
September 402.02 12060.6
October 294.8 9138.73
November 165.7 4971.09
December 118.6 3676.51
Total yearly 125107

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.12% temperature and irradiance loss. This totals to about -15.18%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DorintoshGoodsoilBoyleTelkwaGranisleHazeltonHytheKinusoPouce CoupeDonnellyGirouxvilleRycroftNampaBerwynHines CreekMerrittLourdes-de-Blanc-SablonChatham-KentSt. ThomasSarniaWellandNiagara FallsWoodstockBrantfordSt. CatharinesMurdochville