Solar Calculator Canada

Solar Power Calculator for Invermay, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Invermay
  • GPS Coordinates: 51.8059361, -103.1564472
  • Elevation: 556 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Invermay: 42o
  • Average yearly irradiance: 1452.19 kWh/m2
  • Average yearly power output: 124137 kWh
Sun Path Invermay

Average yearly irradiance delivered by the Sun in Invermay is 1452.19/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 124137 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.58 49.08
February 2.45 68.66
March 3.45 106.95
April 5.32 159.55
May 5.75 178.18
June 5.65 169.61
July 6.17 191.39
August 5.74 177.96
September 4.77 143.17
October 3.51 108.89
November 1.91 57.37
December 1.34 41.39
Total yearly 1452.19

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 153.11 4746.26
February 234.45 6564.68
March 313.51 9718.84
April 460.96 13828.8
May 482.37 14953.4
June 461.26 13837.9
July 498.13 15442.2
August 466.17 14451.3
September 398.85 11965.4
October 306.46 9500.14
November 173.84 5215.08
December 126.21 3912.59
Total yearly 124137

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Invermay solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 96.02 2976.61
February 167.94 4702.38
March 260.27 8068.38
April 436.2 13086
May 501.59 15549.4
June 497.19 14915.8
July 526.37 16317.3
August 458.36 14209.2
September 349.57 10487
October 233.48 7237.73
November 115.7 3471.06
December 76.56 2373.22
Total yearly 113394

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 109.01 3379.24
February 183.54 5139.09
March 274.18 8499.7
April 446.64 13399.1
May 503.77 15616.8
June 495.69 14870.8
July 527.28 16345.6
August 465.34 14425.7
September 363.92 10917.7
October 251.18 7786.43
November 129.1 3872.99
December 87.88 2724.32
Total yearly 116978

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.88 3747.19
February 197.59 5532.59
March 286.19 8871.93
April 454.47 13634.2
May 503.45 15607
June 491.98 14759.4
July 525.17 16280.2
August 469.73 14561.7
September 375.95 11278.6
October 267 8276.9
November 141.32 4239.61
December 98.26 3046.16
Total yearly 119835

Invermay Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.61 4079.83
February 210.08 5882.15
March 296.27 9184.36
April 459.69 13790.6
May 500.34 15510.6
June 485.45 14563.6
July 520.08 16122.6
August 471.51 14616.9
September 385.62 11568.6
October 280.89 8707.51
November 152.33 4569.78
December 107.68 3337.97
Total yearly 121934

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -2.3% temperature and irradiance loss. This totals to about -14.52%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DorintoshGoodsoilBoyleTelkwaGranisleHazeltonHytheKinusoPouce CoupeDonnellyGirouxvilleRycroftNampaBerwynHines CreekMerrittLourdes-de-Blanc-SablonChatham-KentSt. ThomasSarniaWellandNiagara FallsWoodstockBrantfordSt. CatharinesMurdochville