Solar Calculator Canada

Solar Power Calculator for Laird, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Laird
  • GPS Coordinates: 52.7147306, -106.5897194
  • Elevation: 524 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Laird: 44o
  • Average yearly irradiance: 1445.43 kWh/m2
  • Average yearly power output: 123175 kWh
Sun Path Laird

Average yearly irradiance delivered by the Sun in Laird is 1445.43/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 123175 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.62 50.28
February 2.52 70.54
March 3.57 110.76
April 5.05 151.38
May 5.93 183.68
June 5.44 163.17
July 6.13 190.18
August 5.67 175.68
September 4.74 142.2
October 3.39 105.2
November 1.8 54.02
December 1.56 48.35
Total yearly 1445.43

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 156.27 4844.43
February 239.22 6698.16
March 323.51 10028.8
April 435.78 13073.3
May 495.06 15346.9
June 440.87 13226.1
July 491.99 15251.5
August 458.72 14220.4
September 394.09 11822.8
October 294.3 9123.32
November 163.65 4909.51
December 149.36 4630.09
Total yearly 123175

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Laird solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.53 2868.4
February 164.7 4611.53
March 264.53 8200.4
April 410.92 12327.5
May 511.97 15871.1
June 477.66 14329.8
July 521.81 16176
August 449.6 13937.6
September 341.06 10231.8
October 220.48 6834.78
November 104.54 3136.31
December 82.81 2567.13
Total yearly 111092

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.46 3300.13
February 181.82 5090.9
March 279.78 8673.15
April 421.01 12630.3
May 515.48 15979.8
June 476.56 14297
July 522.7 16203.6
August 457.23 14174.2
September 355.81 10674.3
October 237.87 7374.11
November 117.56 3526.93
December 97.24 3014.29
Total yearly 114939

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.25 3696.6
February 197.3 5524.49
March 293.04 9084.11
April 428.66 12859.8
May 516.05 15997.7
June 473.15 14194.5
July 521.11 16154.4
August 462.26 14330.1
September 368.26 11047.7
October 253.46 7857.16
November 129.48 3884.33
December 110.54 3426.87
Total yearly 118058

Laird Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.86 4056.73
February 211.13 5911.61
March 304.27 9432.48
April 433.85 13015.5
May 513.77 15926.9
June 467.48 14024.4
July 516.96 16025.8
August 464.69 14405.3
September 378.36 11350.7
October 267.18 8282.46
November 140.24 4207.33
December 122.69 3803.29
Total yearly 120443

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -2.64% temperature and irradiance loss. This totals to about -14.78%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: