Solar Calculator Canada

Solar Power Calculator for Margo, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Margo
  • GPS Coordinates: 51.8254694, -103.3361014
  • Elevation: 546 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Margo: 43o
  • Average yearly irradiance: 1474.75 kWh/m2
  • Average yearly power output: 126251 kWh
Sun Path Margo

Average yearly irradiance delivered by the Sun in Margo is 1474.75/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 126251 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.7 52.71
February 2.54 71.23
March 3.47 107.66
April 5.31 159.18
May 5.86 181.53
June 5.7 170.92
July 6.23 193.07
August 5.77 178.92
September 4.84 145.13
October 3.59 111.33
November 1.96 58.69
December 1.43 44.37
Total yearly 1474.75

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.33 5125.11
February 244.2 6837.65
March 316.14 9800.47
April 459.66 13789.8
May 491.01 15221.4
June 464.91 13947.4
July 502.51 15577.8
August 468.6 14526.6
September 404.34 12130.2
October 313.2 9709.29
November 178.5 5355.11
December 136.46 4230.41
Total yearly 126251

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Margo solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.93 3159.89
February 173.12 4847.26
March 261.74 8113.98
April 435 13050.1
May 511.01 15841.3
June 502.42 15072.5
July 531.62 16480.1
August 460.82 14285.5
September 353.38 10601.5
October 237.09 7349.7
November 117.55 3526.54
December 80.78 2504.05
Total yearly 114832

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 116.09 3598.65
February 189.5 5305.92
March 275.75 8548.16
April 445.45 13363.7
May 513.56 15920.2
June 501.16 15034.9
July 532.73 16514.7
August 468.01 14508.4
September 368.11 11043.2
October 255.32 7914.97
November 131.36 3940.67
December 93.14 2887.37
Total yearly 118581

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 129.03 4000.04
February 204.27 5719.7
March 287.84 8922.9
April 453.3 13599.1
May 513.47 15917.5
June 497.66 14929.7
July 530.74 16452.9
August 472.57 14649.7
September 380.46 11413.8
October 271.63 8420.38
November 143.96 4318.66
December 104.49 3239.31
Total yearly 121584

Margo Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.75 4363.32
February 217.42 6087.81
March 297.98 9237.45
April 458.53 13755.9
May 510.49 15825.2
June 491.25 14737.3
July 525.73 16297.7
August 474.49 14709.2
September 390.4 11712
October 285.95 8864.32
November 155.31 4659.31
December 114.8 3558.94
Total yearly 123808

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.22% temperature and irradiance loss. This totals to about -14.39%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DorintoshGoodsoilBoyleTelkwaGranisleHazeltonHytheKinusoPouce CoupeDonnellyGirouxvilleRycroftNampaBerwynHines CreekMerrittLourdes-de-Blanc-SablonChatham-KentSt. ThomasSarniaWellandNiagara FallsWoodstockBrantfordSt. CatharinesMurdochville