Solar Calculator Canada

Solar Power Calculator for Melfort, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Melfort
  • GPS Coordinates: 52.8563361, -104.6099722
  • Elevation: 460 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Melfort: 43o
  • Average yearly irradiance: 1464.36 kWh/m2
  • Average yearly power output: 124936 kWh
Sun Path Melfort

Average yearly irradiance delivered by the Sun in Melfort is 1464.36/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 124936 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.62 50.09
February 2.52 70.62
March 3.58 110.94
April 5.25 157.64
May 6.01 186.16
June 5.58 167.36
July 6.18 191.48
August 5.8 179.77
September 4.8 143.92
October 3.49 108.07
November 1.8 53.99
December 1.43 44.31
Total yearly 1464.36

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 156.75 4859.27
February 240.63 6737.62
March 325.49 10090.2
April 454.23 13627
May 501.53 15547.3
June 453.33 13599.8
July 496.65 15396.2
August 469.22 14545.9
September 399.22 11976.6
October 303.26 9401.02
November 164.15 4924.63
December 136.46 4230.37
Total yearly 124936

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Melfort solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.94 2911.99
February 165.7 4639.56
March 266.64 8265.72
April 428.49 12854.8
May 520 16120
June 490.69 14720.8
July 525 16274.9
August 459.18 14234.5
September 345.57 10367
October 225.7 6996.62
November 105.82 3174.5
December 78.28 2426.83
Total yearly 112987

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 107.68 3337.96
February 182.65 5114.18
March 281.67 8731.62
April 439.09 13172.8
May 523.47 16227.6
June 489.19 14675.7
July 526.09 16308.7
August 467.05 14478.7
September 360.6 10818.1
October 243.76 7556.55
November 118.68 3560.54
December 90.93 2818.85
Total yearly 116801

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.27 3728.46
February 197.96 5542.9
March 294.71 9135.98
April 447.13 13413.9
May 524.04 16245.3
June 486.55 14596.6
July 524.96 16273.6
August 472.23 14639.2
September 373.29 11198.8
October 259.95 8058.39
November 130.45 3913.48
December 102.58 3180
Total yearly 119927

Melfort Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.7 4082.58
February 211.61 5925.06
March 305.74 9478.09
April 452.59 13577.7
May 521.65 16171.1
June 480.61 14418.3
July 520.51 16135.7
August 474.75 14717.3
September 383.59 11507.7
October 274.21 8500.62
November 141.07 4232.14
December 113.2 3509.08
Total yearly 122255

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.54% temperature and irradiance loss. This totals to about -14.68%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Crowsnest PassRocky HarbourSourisAssiniboiaCarlyleTwillingateShaunavonHearstFort MacleodTaberVirdenGravelbourgMaple CreekBaie VerteClaresholmBeausejourGull LakeMoosominNeepawaMinnedosaIndian HeadPowerview-Pine FallsHigh RiverPort McNeillGimliMurdochville