Solar Calculator Canada

Solar Power Calculator for Plenty, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Plenty
  • GPS Coordinates: 51.7833517, -108.6444194
  • Elevation: 613 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Plenty: 43o
  • Average yearly irradiance: 1495.03 kWh/m2
  • Average yearly power output: 126604 kWh
Sun Path Plenty

Average yearly irradiance delivered by the Sun in Plenty is 1495.03/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 126604 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.7 52.8
February 2.46 68.81
March 3.51 108.9
April 5.19 155.57
May 5.88 182.41
June 5.59 167.69
July 6.54 202.84
August 5.93 183.91
September 4.99 149.82
October 3.67 113.74
November 2.07 62.22
December 1.49 46.32
Total yearly 1495.03

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.64 5010.88
February 229.87 6436.31
March 313.78 9727.11
April 445.91 13377.4
May 490.63 15209.4
June 452.34 13570.2
July 523.14 16217.2
August 478.03 14819
September 413.3 12399
October 317.18 9832.66
November 187.52 5625.48
December 141.26 4378.92
Total yearly 126604

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Plenty solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.08 3040.36
February 161.26 4515.28
March 261.4 8103.35
April 422.7 12681
May 507.64 15736.9
June 489.04 14671.2
July 552.56 17129.4
August 468.43 14521.3
September 359.6 10787.9
October 240.89 7467.49
November 123.11 3693.42
December 82.33 2552.27
Total yearly 114900

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.29 3480.88
February 177.35 4965.78
March 275.29 8533.93
April 432.53 12975.8
May 510.36 15821
June 487.39 14621.8
July 553.3 17152.3
August 476.29 14765
September 374.81 11244.4
October 259.23 8036.02
November 137.66 4129.65
December 95.37 2956.57
Total yearly 118683

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.34 3885.41
February 191.88 5372.58
March 287.29 8906.1
April 439.9 13197.1
May 510.58 15828.1
June 483.39 14501.6
July 551.3 17090.4
August 481.56 14928.3
September 387.61 11628.3
October 275.62 8544.14
November 150.94 4528.23
December 107.38 3328.73
Total yearly 121739

Plenty Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 137.19 4252.75
February 204.82 5735.01
March 297.39 9219.02
April 444.8 13344
May 507.99 15747.6
June 477.61 14328.4
July 547.11 16960.5
August 484.08 15006.4
September 397.97 11939
October 290.01 8990.29
November 162.93 4887.9
December 118.31 3667.62
Total yearly 124078

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -3.27% temperature and irradiance loss. This totals to about -15.32%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.