Solar Calculator Canada

Solar Power Calculator for Valparaiso, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Valparaiso
  • GPS Coordinates: 52.850839, -104.18152
  • Elevation: 459 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Valparaiso: 43o
  • Average yearly irradiance: 1459.46 kWh/m2
  • Average yearly power output: 124507 kWh
Sun Path Valparaiso

Average yearly irradiance delivered by the Sun in Valparaiso is 1459.46/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 124507 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.66 51.5
February 2.57 71.92
March 3.59 111.27
April 5.21 156.42
May 5.93 183.71
June 5.58 167.27
July 6.15 190.53
August 5.75 178.22
September 4.7 140.95
October 3.5 108.44
November 1.79 53.78
December 1.47 45.47
Total yearly 1459.46

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.52 5007.15
February 245.39 6871
March 325.88 10102.3
April 450.04 13501.2
May 494.66 15334.6
June 452.38 13571.4
July 493.71 15304.9
August 464.99 14414.8
September 390.79 11723.6
October 304.11 9427.48
November 163.35 4900.57
December 140.26 4347.99
Total yearly 124507

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Valparaiso solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 97.14 3011.25
February 169.91 4757.62
March 266.63 8265.49
April 424.38 12731.3
May 513.45 15916.9
June 490.22 14706.5
July 522.49 16197.1
August 455.42 14118.1
September 339.18 10175.5
October 226.79 7030.53
November 104.98 3149.32
December 80.43 2493.3
Total yearly 112553

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.22 3447.75
February 187.07 5238.06
March 281.76 8734.71
April 434.91 13047.4
May 516.68 16017
June 488.67 14660.1
July 523.64 16232.8
August 463.13 14357.1
September 353.7 10611
October 244.85 7590.49
November 117.81 3534.36
December 93.42 2896.11
Total yearly 116367

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.12 3847.78
February 202.57 5671.94
March 294.91 9142.1
April 442.91 13287.4
May 517.16 16031.8
June 485.88 14576.3
July 522.46 16196.3
August 468.2 14514.3
September 365.93 10977.9
October 261.03 8092
November 129.54 3886.28
December 105.39 3267.1
Total yearly 119491

Valparaiso Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.82 4210.45
February 216.38 6058.59
March 306.03 9486.94
April 448.36 13450.7
May 514.7 15955.7
June 479.84 14395.3
July 518.02 16058.5
August 470.65 14590.2
September 375.84 11275.2
October 275.28 8533.6
November 140.13 4203.93
December 116.29 3605.07
Total yearly 121824

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -2.53% temperature and irradiance loss. This totals to about -14.69%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville