Solar Calculator Canada

Solar Power Calculator for Weirdale, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Weirdale
  • GPS Coordinates: 53.447274, -105.239974
  • Elevation: 473 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Weirdale: 44o
  • Average yearly irradiance: 1402.82 kWh/m2
  • Average yearly power output: 118941 kWh
Sun Path Weirdale

Average yearly irradiance delivered by the Sun in Weirdale is 1402.82/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 118941 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.52 47.07
February 2.46 68.98
March 3.71 115.05
April 5.11 153.36
May 5.83 180.58
June 5.41 162.24
July 5.87 182.03
August 5.46 169.11
September 4.5 134.85
October 3.16 97.84
November 1.67 50.13
December 1.34 41.59
Total yearly 1402.82

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.49 4510.19
February 232.44 6508.38
March 334.55 10371.1
April 439.44 13183.2
May 483.76 14996.4
June 436.89 13106.6
July 469.01 14539.3
August 439.17 13614.2
September 371.87 11156
October 272.56 8449.44
November 151.67 4549.99
December 127.63 3956.47
Total yearly 118941

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Weirdale solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 86.39 2677.98
February 161.5 4521.96
March 274.69 8515.31
April 411.69 12350.7
May 497.4 15419.5
June 470.24 14107.2
July 496.23 15383.2
August 429.49 13314.2
September 321.84 9655.2
October 203.85 6319.46
November 96.34 2890.24
December 70.9 2197.96
Total yearly 107353

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 99.43 3082.39
February 178.02 4984.47
March 290.36 9001.12
April 422.2 12666
May 500.92 15528.6
June 468.83 14065
July 497.19 15412.8
August 436.7 13537.7
September 335.79 10073.7
October 220.02 6820.58
November 108.57 3257.02
December 83.11 2576.38
Total yearly 111006

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.39 3452.95
February 192.92 5401.68
March 303.96 9422.84
April 430.23 12907
May 501.7 15552.6
June 466.71 14001.2
July 496.07 15378.1
August 441.43 13684.2
September 347.56 10426.9
October 234.51 7269.69
November 119.75 3592.51
December 94.38 2925.7
Total yearly 114015

Weirdale Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 122.22 3788.8
February 206.18 5773.15
March 315.48 9779.97
April 435.78 13073.3
May 499.62 15488.1
June 461.31 13839.2
July 491.93 15249.9
August 443.71 13755.1
September 357.13 10714
October 247.27 7665.43
November 129.85 3895.63
December 104.66 3244.46
Total yearly 116267

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -3.11% temperature and irradiance loss. This totals to about -15.21%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Port MoodyCoquitlamNorth VancouverArmstrongEnderbyMartensvilleWarmanBeaumontLaSalleLakeshoreAylmerTillsonburgPetroliaFort EriePlympton-WyomingIngersollPelhamLincolnGrimsbyNiagara-on-the-LakeSouth HuronOakvilleBluewaterMiltonHuron EastMurdochville