Solar Calculator Canada

Solar Power Calculator for Coutts, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Coutts
  • GPS Coordinates: 49.0027778, -111.9588889
  • Elevation: 1062 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Coutts: 41o
  • Average yearly irradiance: 1656.11 kWh/m2
  • Average yearly power output: 139274 kWh
Sun Path Coutts

Average yearly irradiance delivered by the Sun in Coutts is 1656.11/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 139274 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.22 68.87
February 3.1 86.9
March 4.23 130.99
April 5.42 162.61
May 5.77 178.82
June 6.04 181.2
July 7.06 218.9
August 6.47 200.54
September 5.28 158.43
October 3.92 121.55
November 2.73 81.86
December 2.11 65.43
Total yearly 1656.11

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.06 6294.97
February 279.15 7816.24
March 370.38 11481.8
April 464.37 13931
May 480.16 14885
June 490.22 14706.7
July 560.02 17360.6
August 515.75 15988.3
September 433.49 13004.6
October 336.59 10434.3
November 244.42 7332.49
December 194.76 6037.64
Total yearly 139274

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Coutts solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 134.18 4159.51
February 209.73 5872.52
March 319.04 9890.32
April 446.35 13390.6
May 501.8 15555.7
June 532.8 15984
July 596.82 18501.5
August 509.14 15783.2
September 385.7 11570.9
October 265.72 8237.26
November 168.65 5059.39
December 121.19 3756.82
Total yearly 127762

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.48 4664.75
February 226.96 6354.86
March 333.45 10336.8
April 455.14 13654.1
May 502.54 15578.7
June 529.16 15874.9
July 595.62 18464.1
August 516.45 16010
September 400.24 12007.2
October 283.74 8795.95
November 186.74 5602.05
December 138.41 4290.58
Total yearly 131634

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.35 5125.92
February 242.4 6787.09
March 345.72 10717.3
April 461.34 13840.1
May 501.04 15532.2
June 523.11 15693.2
July 591.51 18336.7
August 521.03 16152.1
September 412.24 12367.2
October 299.73 9291.52
November 203.19 6095.76
December 154.22 4780.77
Total yearly 134720

Coutts Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.77 5541.78
February 256.01 7168.21
March 355.83 11030.6
April 464.91 13947.2
May 497.28 15415.7
June 514.91 15447.3
July 585.08 18137.5
August 522.57 16199.8
September 421.66 12649.9
October 313.62 9722.36
November 217.97 6539.06
December 168.57 5225.65
Total yearly 137025

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.95% temperature and irradiance loss. This totals to about -15.9%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville