Solar Calculator Canada

Solar Power Calculator for Chamberlain, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chamberlain
  • GPS Coordinates: 50.85146, -105.568651
  • Elevation: 570 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chamberlain: 43o
  • Average yearly irradiance: 1527.54 kWh/m2
  • Average yearly power output: 129873 kWh
Sun Path Chamberlain

Average yearly irradiance delivered by the Sun in Chamberlain is 1527.54/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 129873 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.94 60
February 2.69 75.45
March 3.66 113.37
April 5.36 160.83
May 5.76 178.45
June 5.68 170.25
July 6.51 201.69
August 5.88 182.25
September 5.02 150.71
October 3.71 115.03
November 2.23 66.81
December 1.7 52.7
Total yearly 1527.54

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.26 5743.2
February 255 7139.97
March 328.89 10195.6
April 461.59 13847.8
May 480.27 14888.5
June 460.33 13809.9
July 520.93 16148.8
August 472.58 14649.9
September 415.94 12478.2
October 320.76 9943.42
November 201.12 6033.5
December 161.12 4994.62
Total yearly 129873

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chamberlain solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.35 3575.82
February 181.96 5094.82
March 276.49 8571.19
April 436.9 13107
May 498.91 15466.3
June 498.46 14953.8
July 553.13 17147.1
August 466.55 14463.2
September 364.29 10928.8
October 245.8 7619.83
November 133.91 4017.15
December 95.02 2945.49
Total yearly 117890

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.21 4067.39
February 199.44 5584.22
March 290.64 9009.98
April 447.01 13410.3
May 501.24 15538.4
June 496.92 14907.7
July 553.84 17169.1
August 473.57 14680.8
September 379.19 11375.7
October 263.97 8183.12
November 149.27 4478.16
December 109.91 3407.21
Total yearly 121812

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.72 4517.25
February 215.2 6025.69
March 302.81 9387.19
April 454.54 13636.2
May 500.67 15520.6
June 492.93 14788
July 551.85 17107.5
August 477.88 14814.4
September 391.64 11749.3
October 280.17 8685.37
November 163.28 4898.51
December 123.58 3831.1
Total yearly 124961

Chamberlain Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.85 4924.47
February 229.23 6418.32
March 312.97 9702.02
April 459.46 13783.7
May 497.46 15421.3
June 486.11 14583.3
July 546.54 16942.7
August 479.53 14865.3
September 401.61 12048.3
October 294.36 9125.07
November 175.9 5276.97
December 136 4216.13
Total yearly 127308

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -2.92% temperature and irradiance loss. This totals to about -14.98%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Bittern LakeWeldonPayntonLeaskParadise ValleyMeotaZenon ParkBretonParksideWarburgEdamAylshamMarshallHay LakesHoldenCodetteRyleyMedsteadShell LakeMervinMannvilleKitscotyGlaslynCanwoodInnisfreeMurdochville