The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Standard
  • GPS Coordinates: 51.1097222, -112.9836111
  • Elevation: 895 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Standard: 42o
  • Average yearly irradiance: 1526.22 kWh/m2
  • Average yearly power output: 127695 kWh
Sun Path Standard

Average yearly irradiance delivered by the Sun in Standard is 1526.22/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 127695 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.9 59.03
February 2.62 73.36
March 3.52 109.01
April 5.11 153.38
May 5.8 179.91
June 5.87 176.22
July 6.66 206.46
August 5.98 185.4
September 5.02 150.72
October 3.72 115.42
November 2.35 70.56
December 1.51 46.76
Total yearly 1526.22

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.08 5396.61
February 235.69 6599.35
March 305.9 9482.84
April 435.44 13063.1
May 479.55 14866.1
June 474.61 14238.4
July 528.49 16383.2
August 477.81 14812.2
September 412.38 12371.5
October 318.92 9886.53
November 210.44 6313.16
December 138.13 4282.13
Total yearly 127695

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Standard solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.36 3421.02
February 171.3 4796.51
March 259.02 8029.66
April 416.33 12489.8
May 496.5 15391.6
June 511.85 15355.4
July 557.71 17289
August 468.93 14536.7
September 362.81 10884.2
October 245.89 7622.48
November 139.78 4193.32
December 83.67 2593.66
Total yearly 116603

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.06 3876.71
February 186.81 5230.73
March 271.75 8424.3
April 425.08 12752.5
May 498.39 15450
June 509.58 15287.4
July 557.94 17296
August 476.37 14767.5
September 377.37 11321.2
October 263.91 8181.07
November 156.19 4685.83
December 96.12 2979.63
Total yearly 120253

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.49 4293.17
February 200.74 5620.78
March 282.69 8763.37
April 431.6 12948
May 497.89 15434.7
June 504.97 15149.1
July 555.48 17219.8
August 481.28 14919.6
September 389.53 11685.8
October 279.96 8678.77
November 171.15 5134.64
December 107.53 3333.46
Total yearly 123181

Standard Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.63 4669.49
February 213.08 5966.14
March 291.81 9046.05
April 435.57 13067
May 495.37 15356.3
June 498.17 14945
July 550.79 17074.3
August 483.42 14985.9
September 399.24 11977.1
October 294.01 9114.23
November 184.62 5538.6
December 117.88 3654.27
Total yearly 125395

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -4.44% temperature and irradiance loss. This totals to about -16.33%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Bittern LakeWeldonPayntonLeaskParadise ValleyMeotaZenon ParkBretonParksideWarburgEdamAylshamMarshallHay LakesHoldenCodetteRyleyMedsteadShell LakeMervinMannvilleKitscotyGlaslynCanwoodInnisfreeMurdochville