Solar Calculator Canada

Solar Power Calculator for Goodeve, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Goodeve
  • GPS Coordinates: 51.0630639, -103.1884667
  • Elevation: 642 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Goodeve: 43o
  • Average yearly irradiance: 1551.58 kWh/m2
  • Average yearly power output: 132944 kWh
Sun Path Goodeve

Average yearly irradiance delivered by the Sun in Goodeve is 1551.58/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 132944 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.98 61.53
February 3.07 85.83
March 3.62 112.12
April 5.42 162.75
May 5.85 181.42
June 5.68 170.44
July 6.36 197.2
August 5.91 183.1
September 5.16 154.72
October 3.79 117.51
November 2.32 69.54
December 1.79 55.42
Total yearly 1551.58

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.95 5950.57
February 292.82 8198.93
March 326.84 10132.2
April 469.34 14080.3
May 490.95 15219.3
June 462.82 13884.6
July 511.71 15863
August 478.51 14833.7
September 430.14 12904.1
October 330 10229.9
November 211.81 6354.23
December 170.76 5293.62
Total yearly 132944

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Goodeve solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.53 3705.49
February 206.85 5791.7
March 274.44 8507.59
April 446.61 13398.2
May 513.01 15903.2
June 505.13 15153.8
July 546.04 16927.1
August 473.93 14691.8
September 376.23 11286.9
October 250.53 7766.45
November 139.67 4190.07
December 100.46 3114.41
Total yearly 120437

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.72 4207.17
February 226.79 6350.13
March 288.38 8939.66
April 456.78 13703.3
May 515.25 15972.6
June 503.26 15097.7
July 546.94 16955.1
August 480.97 14910.1
September 391.8 11753.9
October 269.52 8355.21
November 155.94 4678.24
December 116 3595.95
Total yearly 124519

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.5 4665.51
February 244.76 6853.26
March 300.35 9310.83
April 464.31 13929.2
May 514.87 15961.1
June 499.21 14976.2
July 544.58 16882
August 485.31 15044.5
September 404.82 12144.7
October 286.48 8880.87
November 170.77 5123.17
December 130.26 4038.07
Total yearly 127809

Goodeve Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 163.86 5079.72
February 260.73 7300.32
March 310.33 9620.31
April 469.17 14075.2
May 511.63 15860.7
June 492.22 14766.7
July 539.14 16713.2
August 486.93 15094.9
September 415.27 12458.2
October 301.35 9341.79
November 184.12 5523.64
December 143.21 4439.6
Total yearly 130274

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -2.15% temperature and irradiance loss. This totals to about -14.32%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Bittern LakeWeldonPayntonLeaskParadise ValleyMeotaZenon ParkBretonParksideWarburgEdamAylshamMarshallHay LakesHoldenCodetteRyleyMedsteadShell LakeMervinMannvilleKitscotyGlaslynCanwoodInnisfreeMurdochville