Solar Calculator Canada

Solar Power Calculator for Nanton, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Nanton
  • GPS Coordinates: 50.35, -113.7666667
  • Elevation: 1019 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Nanton: 42o
  • Average yearly irradiance: 1591.69 kWh/m2
  • Average yearly power output: 132578 kWh
Sun Path Nanton

Average yearly irradiance delivered by the Sun in Nanton is 1591.69/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 132578 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.21 68.48
February 3.01 84.19
March 4.06 125.91
April 5.18 155.33
May 5.76 178.58
June 5.72 171.72
July 6.69 207.32
August 6.08 188.36
September 5.12 153.52
October 3.81 118.05
November 2.66 79.91
December 1.95 60.32
Total yearly 1591.69

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 198.12 6141.81
February 266 7447.86
March 352.36 10923
April 438.06 13141.7
May 473.68 14684
June 460.69 13820.8
July 528.12 16371.7
August 482.35 14952.8
September 417.37 12521.1
October 323.71 10035
November 236.42 7092.68
December 175.68 5446.04
Total yearly 132578

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Nanton solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.22 3974.79
February 198.47 5557.27
March 300.4 9312.49
April 420.19 12605.7
May 492.64 15271.9
June 500.14 15004.3
July 560.33 17370.3
August 475.38 14736.8
September 368.92 11067.5
October 251.73 7803.62
November 158.18 4745.43
December 107.18 3322.63
Total yearly 120773

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.38 4475.83
February 214.82 6014.9
March 314.55 9750.99
April 428.72 12861.8
May 494.15 15318.7
June 497.35 14920.5
July 560.08 17362.5
August 482.58 14960.1
September 383.26 11497.9
October 269.54 8355.62
November 176.28 5288.52
December 122.82 3807.53
Total yearly 124615

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 159.1 4932.04
February 229.44 6424.25
March 326.67 10126.7
April 434.94 13048.1
May 493.38 15294.7
June 492.34 14770.3
July 557.37 17278.5
August 487.1 15100.1
September 395.17 11855.2
October 285.35 8845.92
November 192.75 5782.46
December 137.15 4251.6
Total yearly 127710

Nanton Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.35 5342.78
February 242.31 6784.73
March 336.73 10438.8
April 438.65 13159.5
May 490.63 15209.4
June 485.49 14564.7
July 552.24 17119.3
August 488.87 15155.1
September 404.63 12138.8
October 299.14 9273.4
November 207.54 6226.15
December 150.12 4653.72
Total yearly 130066

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -4.89% temperature and irradiance loss. This totals to about -16.71%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Birch HillsMaidstoneVikingMilletArborfieldLashburnShellbrookThorsbyCalmarCarrot RiverDevonSpiritwoodTofieldTurtlefordChoicelandStony PlainMundareSt. WalburgTwo HillsLamontBruderheimMorinvilleGibbonsBig RiverBon AccordMurdochville