Solar Calculator Canada

Solar Power Calculator for Mervin, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mervin
  • GPS Coordinates: 53.3334617, -108.8740111
  • Elevation: 582 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mervin: 44o
  • Average yearly irradiance: 1435.21 kWh/m2
  • Average yearly power output: 122224 kWh
Sun Path Mervin

Average yearly irradiance delivered by the Sun in Mervin is 1435.21/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 122224 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.43 44.45
February 2.47 69.26
March 3.56 110.45
April 5.05 151.46
May 5.88 182.39
June 5.52 165.7
July 6.19 191.94
August 5.48 169.91
September 4.74 142.18
October 3.48 107.79
November 1.9 56.87
December 1.38 42.81
Total yearly 1435.21

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.35 4226.86
February 233.38 6534.78
March 322.96 10011.8
April 436.53 13096
May 490.9 15218
June 448.79 13463.7
July 497.82 15432.5
August 444.43 13777.3
September 394.71 11841.2
October 302.09 9364.87
November 172.63 5178.82
December 131.55 4077.96
Total yearly 122224

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mervin solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 81.31 2520.76
February 160.7 4499.66
March 264.71 8205.95
April 410.57 12317.2
May 506.88 15713.4
June 484.07 14522.1
July 525.55 16292.2
August 435.07 13487.2
September 340.15 10204.5
October 223.38 6924.84
November 108.48 3254.36
December 72.88 2259.17
Total yearly 110201

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.32 2892.97
February 177.25 4962.93
March 279.62 8668.33
April 420.89 12626.8
May 510.29 15819
June 483.41 14502.4
July 526.69 16327.4
August 442.46 13716.1
September 355.19 10655.7
October 241.68 7491.98
November 122.54 3676.3
December 85.51 2650.7
Total yearly 113991

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.34 3234.57
February 192.2 5381.61
March 292.58 9069.97
April 428.78 12863.3
May 511.15 15845.7
June 480.07 14402
July 525.2 16281.2
August 447.47 13871.6
September 367.92 11037.5
October 258.1 8000.97
November 135.42 4062.66
December 97.16 3011.89
Total yearly 117063

Mervin Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.34 3544.6
February 205.54 5755.11
March 303.55 9410.09
April 434.23 13026.8
May 509.3 15788.4
June 474.82 14244.5
July 521.4 16163.4
August 450.05 13951.4
September 378.32 11349.6
October 272.59 8450.26
November 147.07 4412.21
December 107.79 3341.36
Total yearly 119438

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -2.71% temperature and irradiance loss. This totals to about -14.84%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

D�gelisLa MalbaieT�miscouata-sur-le-LacRivi�re-du-LoupCampbelltonPasp�biacTrois-PistolesMalarticNew RichmondRouyn-NorandaChandlerCausapscalSenneterreAmquiRobervalPerc�AlmaAmosMont-JoliSaint-F�licienForestvilleDuncanLa SarreMataneDolbeau-MistassiniMurdochville