Solar Calculator Canada

Solar Power Calculator for Warburg, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Warburg
  • GPS Coordinates: 53.1783334, -114.3208333
  • Elevation: 821 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Warburg: 43o
  • Average yearly irradiance: 1451.36 kWh/m2
  • Average yearly power output: 121834 kWh
Sun Path Warburg

Average yearly irradiance delivered by the Sun in Warburg is 1451.36/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 121834 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.59 49.43
February 2.53 70.88
March 3.53 109.46
April 5.07 152.12
May 5.86 181.68
June 5.76 172.82
July 6.21 192.52
August 5.66 175.54
September 4.65 139.45
October 3.33 103.13
November 2.09 62.61
December 1.35 41.72
Total yearly 1451.36

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.58 4512.94
February 227.86 6380.03
March 309.01 9579.32
April 433.25 12997.4
May 485.89 15062.7
June 466.89 14006.6
July 495.39 15356.9
August 455.62 14124.2
September 383.52 11505.6
October 285.96 8864.62
November 187.15 5614.48
December 123.53 3829.34
Total yearly 121834

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Warburg solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 90.45 2803.89
February 164.5 4605.99
March 259.72 8051.18
April 409.79 12293.7
May 500.11 15503.5
June 499.04 14971.2
July 519.78 16113.2
August 443.99 13763.6
September 334.08 10022.5
October 216.45 6709.8
November 120.47 3614.11
December 73.04 2264.18
Total yearly 110717

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 102.97 3191.98
February 179.57 5028
March 272.85 8458.42
April 419.31 12579.2
May 502.73 15584.7
June 497.83 14935
July 520.74 16143
August 451.67 14001.8
September 348.2 10446
October 233.16 7227.97
November 135.55 4066.56
December 84.34 2614.52
Total yearly 114277

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.41 3546.81
February 193.12 5407.41
March 284.17 8809.17
April 426.51 12795.2
May 502.94 15591
June 494.32 14829.5
July 519.26 16097
August 456.95 14165.6
September 360.07 10802.1
October 248.11 7691.29
November 149.33 4479.99
December 94.7 2935.64
Total yearly 117151

Warburg Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.76 3867.67
February 205.13 5743.66
March 293.64 9102.89
April 431.32 12939.6
May 500.93 15528.9
June 488.61 14658.2
July 515.59 15983.3
August 459.65 14249.2
September 369.68 11090.3
October 261.24 8098.49
November 161.77 4853.25
December 104.09 3226.92
Total yearly 119342

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -4.09% temperature and irradiance loss. This totals to about -16.06%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.