Solar Calculator Canada

Solar Power Calculator for Canwood, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Canwood
  • GPS Coordinates: 53.35934, -106.603417
  • Elevation: 516 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Canwood: 43o
  • Average yearly irradiance: 1402.35 kWh/m2
  • Average yearly power output: 118871 kWh
Sun Path Canwood

Average yearly irradiance delivered by the Sun in Canwood is 1402.35/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 118871 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.43 44.26
February 2.47 69.05
March 3.71 115.12
April 5.09 152.67
May 5.8 179.92
June 5.41 162.23
July 6.05 187.59
August 5.55 172.11
September 4.48 134.39
October 3.17 98.36
November 1.59 47.79
December 1.25 38.87
Total yearly 1402.35

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.51 4200.73
February 231.85 6491.85
March 334.72 10376.2
April 438.43 13152.9
May 483.24 14980.6
June 437.35 13120.6
July 484.2 15010.1
August 448.47 13902.6
September 371.57 11147
October 274.27 8502.28
November 143.9 4316.87
December 118.38 3669.64
Total yearly 118871

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Canwood solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 81.92 2539.38
February 161.18 4512.93
March 274.44 8507.51
April 411.78 12353.3
May 497.24 15414.5
June 470.86 14125.9
July 511.12 15844.6
August 438.33 13588.2
September 321.99 9659.82
October 206.23 6393.11
November 92.71 2781.17
December 67.38 2088.81
Total yearly 107809

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.91 2911.15
February 177.6 4972.88
March 290.17 8995.27
April 422.16 12664.9
May 500.77 15523.9
June 469.92 14097.7
July 512.19 15878
August 445.86 13821.6
September 335.82 10074.6
October 222.44 6895.67
November 104.19 3125.77
December 78.71 2440.03
Total yearly 111401

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.89 3251.56
February 192.44 5388.29
March 303.83 9418.71
April 430.09 12902.6
May 501.46 15545.2
June 466.75 14002.4
July 510.73 15832.7
August 450.88 13977.3
September 347.48 10424.5
October 236.97 7345.99
November 114.69 3440.6
December 89.14 2763.35
Total yearly 114293

Canwood Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.84 3559.9
February 205.66 5758.57
March 315.39 9777.23
April 435.54 13066.3
May 499.38 15480.6
June 461.49 13844.6
July 506.93 15714.8
August 453.36 14054.2
September 356.95 10708.5
October 249.76 7742.62
November 124.16 3724.75
December 98.64 3057.73
Total yearly 116490

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -3.09% temperature and irradiance loss. This totals to about -15.23%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

MurdochvilleGrand ForksLebel-sur-Qu�villonTrailCap-ChatNanaimoWinklerBaie-ComeauPort AlberniParksvilleCastlegarNelsonPentictonFernieSteinbachWeyburnKimberleyCourtenayMatagamiChapaisPowell RiverPortage la PrairiePort-CartierCampbell RiverMedicine HatMurdochville