Solar Calculator Canada

Solar Power Calculator for Senneterre, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Senneterre
  • GPS Coordinates: 48.390435, -77.240452
  • Elevation: 306 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Senneterre: 40o
  • Average yearly irradiance: 1409.22 kWh/m2
  • Average yearly power output: 120010 kWh
Sun Path Senneterre

Average yearly irradiance delivered by the Sun in Senneterre is 1409.22/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 120010 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.34 72.69
February 3.35 93.7
March 4.6 142.45
April 4.71 141.21
May 5.33 165.18
June 5.4 162.11
July 5.3 164.3
August 4.89 151.71
September 4.22 126.58
October 2.74 85.02
November 1.84 55.1
December 1.59 49.17
Total yearly 1409.22

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 226.24 7013.4
February 317.7 8895.62
March 417.65 12947.1
April 406.35 12190.4
May 439.5 13624.4
June 433.75 13012.5
July 422.56 13099.4
August 393.64 12202.8
September 346.66 10399.8
October 232.56 7209.5
November 161.18 4835.54
December 147.74 4579.85
Total yearly 120010

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Senneterre solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 157.88 4894.3
February 246.46 6900.8
March 362.82 11247.3
April 396.36 11890.9
May 460.04 14261.1
June 468.66 14059.9
July 450.44 13963.7
August 395.79 12269.4
September 316.87 9506.18
October 194.81 6039.15
November 119.42 3582.55
December 100.74 3122.85
Total yearly 111738

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.78 5418.29
February 264.79 7414.18
March 378.71 11740
April 402.67 12080
May 460.55 14277
June 465.79 13973.8
July 448.9 13915.9
August 399.48 12383.8
September 326.76 9802.85
October 205.11 6358.3
November 129.91 3897.19
December 112.32 3481.89
Total yearly 114743

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.12 5893.84
February 281.14 7871.92
March 392.18 12157.6
April 406.82 12204.5
May 458.62 14217.3
June 461.23 13836.8
July 445.63 13814.7
August 401.04 12432.4
September 334.71 10041.4
October 214.07 6636.22
November 139.37 4181.09
December 122.84 3808.09
Total yearly 117096

Senneterre Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.87 6320.07
February 295.47 8273.04
March 403.2 12499.1
April 408.81 12264.2
May 454.39 14086.2
June 454.09 13622.6
July 439.89 13636.7
August 400.55 12417.1
September 340.7 10221.1
October 221.68 6871.93
November 147.78 4433.29
December 132.29 4100.92
Total yearly 118746

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -2.59% temperature and irradiance loss. This totals to about -14.84%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: