Solar Calculator Canada

Solar Power Calculator for Rouyn-Noranda, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Rouyn-Noranda
  • GPS Coordinates: 48.233333, -79.016667
  • Elevation: 285 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Rouyn-Noranda: 40o
  • Average yearly irradiance: 1462.29 kWh/m2
  • Average yearly power output: 124381 kWh
Sun Path Rouyn-Noranda

Average yearly irradiance delivered by the Sun in Rouyn-Noranda is 1462.29/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 124381 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.53 78.58
February 3.53 98.92
March 4.6 142.63
April 4.8 144.08
May 5.48 169.8
June 5.61 168.21
July 5.57 172.7
August 5.2 161.06
September 4.32 129.46
October 2.9 89.85
November 1.91 57.38
December 1.6 49.61
Total yearly 1462.29

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 244.58 7582.08
February 335.05 9381.41
March 417.06 12928.8
April 412.85 12385.6
May 451.81 14006.2
June 450.3 13509
July 443.89 13760.6
August 416.95 12925.5
September 353.56 10606.9
October 246.13 7629.95
November 168.15 5044.44
December 149.04 4620.11
Total yearly 124381

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Rouyn-Noranda solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.71 5198.99
February 258.06 7225.57
March 362.14 11226.2
April 402.98 12089.5
May 472.26 14640.1
June 486.56 14596.9
July 472.64 14651.7
August 417.85 12953.4
September 322.35 9670.56
October 204.55 6340.92
November 124.16 3724.89
December 101.79 3155.35
Total yearly 115474

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.56 5783.44
February 277.79 7778.02
March 378.04 11719.3
April 409.4 12282
May 472.92 14660.4
June 483.48 14504.3
July 471.06 14602.7
August 422.17 13087.2
September 332.62 9978.64
October 215.75 6688.29
November 135.14 4054.21
December 113.39 3515
Total yearly 118653

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.69 6314.41
February 295.39 8271.02
March 391.53 12137.3
April 413.63 12409
May 471.16 14606
June 478.56 14356.9
July 467.53 14493.3
August 424.24 13151.3
September 340.9 10227.1
October 225.53 6991.43
November 145.06 4351.79
December 123.93 3841.92
Total yearly 121152

Rouyn-Noranda Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.06 6790.88
February 310.84 8703.57
March 402.55 12479.2
April 415.65 12469.5
May 466.94 14475.2
June 471.39 14141.6
July 461.99 14321.8
August 424.14 13148.3
September 347.15 10414.4
October 233.85 7249.34
November 153.88 4616.49
December 133.4 4135.47
Total yearly 122946

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -2.74% temperature and irradiance loss. This totals to about -14.94%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: